Medscape Medical NewsAll articles

EyeBOX

Oculogica, Inc. • Neurology • 12/28/2018

De NovoIEC 62304 Class B
FDA Summary PDF

Device Purpose

The EyeBOX device aims to provide an objective assessment for concussions by utilizing electroencephalography (EEG) and eye-tracking technology to analyze responses to visual stimuli in patients shortly after a head injury. It employs trained classifiers to derive a quantitative score from oculomotor and EEG metrics, demonstrating notable sensitivity and specificity in identifying injuries corroborated by CT scans, thus serving as a supplementary diagnostic tool.

Summary

The EyeBOX device is designed for the objective evaluation of concussions in individuals aged 5 to 67, specifically within one week following a head injury. The methodology involves patients wearing an electroencephalography (EEG) headset while observing moving visual stimuli. During this process, the EyeBOX system concurrently records the patient's eye movements and EEG data, which is then processed to extract critical oculomotor and quantitative EEG (qEEG) metrics, forming the basis for a scientifically derived score. The system further utilizes trained classifiers, which compare the patient's acquired data against established data from trauma cohorts to calculate a concussion likelihood score ranging from 0 to 20. Clinical studies have demonstrated the EyeBOX's efficacy, showing approximately 90% sensitivity and 80% specificity in detecting injuries that were also positive on CT scans, positioning it as an objective, supplementary diagnostic tool to augment traditional neurological examinations in the assessment of mild head trauma.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

EyeBOXConcussionEEGOculomotor metricsQuantitative EEG (qEEG)Head injuryVisual stimuliSensitivitySpecificityCT scan

Device Metadata

Submission Number
DEN170091
Company
Oculogica, Inc.
Panel
Neurology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
diagnosis

Relevant Clinical Questions

  • Q1. How does the EyeBOX score correlate with the severity of concussion symptoms or long-term outcomes in patients who are CT-negative but clinically symptomatic?; What specific oculomotor and quantitative EEG metrics contribute most significantly to the EyeBOX score, and how are these metrics weighted by the trained classifiers?; How does the performance of EyeBOX (sensitivity/specificity) vary across different age groups within the 5-67 range, and are there adjustments in the algorithm for pediatric versus adult populations?; What is the test-retest reliability of the EyeBOX score in stable individuals, and how susceptible is the device to factors like fatigue, medication, or pre-existing neurological conditions unrelated to the acute head injury?; Beyond identifying CT-positive injuries, how effective is EyeBOX in differentiating between concussions and other non-structural head injuries or in tracking recovery trajectories over time?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via De Novo pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
EyeBOX - Oculogica, Inc. | ESL FDA AI Device Intelligence