Medscape Medical NewsAll articles

IDx-DR

IDx, LLC • Ophthalmic • 04/11/2018

De NovoIEC 62304 Class A
FDA Summary PDF

Device Purpose

IDx-DR is an autonomous AI system designed to detect more-than-mild diabetic retinopathy (mtmDR) in adults with diabetes by analyzing fundus photographs using a machine learning algorithm. It aims to improve screening efficiency and facilitate timely referrals in primary care settings through its AI-driven image interpretation and clear diagnostic outputs, validated by strong clinical trial performance.

Summary

IDx-DR is an autonomous artificial intelligence (AI) system specifically engineered for screening adults with diabetes for diabetic retinopathy (DR), particularly those who have not been previously diagnosed with the condition. The system's methodology involves the automated analysis of nonmydriatic fundus photographs to detect the presence of more-than-mild diabetic retinopathy (mtmDR). The underlying science of IDx-DR is rooted in its sophisticated AI algorithm, which was developed and trained using extensive datasets of expertly annotated retinal images, enabling it to independently interpret these images and identify signs of mtmDR. The system is designed to provide one of three distinct outputs following image analysis: "mtmDR detected," "not detected," or "inadequate image." This clear output empowers primary care providers to make informed decisions regarding patient referrals to specialists, without the immediate need for an ophthalmologist's consultation. In its pivotal clinical trial, IDx-DR demonstrated high diagnostic accuracy, achieving a sensitivity of 87.2% and a specificity of 90.7% for identifying mtmDR. As the first fully autonomous AI diagnostic tool for DR, IDx-DR represents a significant advancement in improving the efficiency of DR screening and patient triage processes, especially beneficial in healthcare settings outside of specialized eye care facilities, such as primary care clinics.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

IDx-DRAutonomous AIDiabetic Retinopathy (DR)ScreeningFundus PhotographsMore-than-mild DR (mtmDR)SensitivitySpecificityPrimary CareTriage

Device Metadata

Submission Number
DEN180001
Company
IDx, LLC
Panel
Ophthalmic
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
diagnosis

Relevant Clinical Questions

  • Q1. How does IDx-DR's performance (sensitivity and specificity) compare to human expert graders in real-world primary care settings beyond the initial clinical trial?; What are the specific criteria used by the AI to determine 'inadequate image' quality, and what is the typical rate of such outcomes?; How does the system handle progression of DR over time if used for longitudinal screening, or is it primarily intended for initial detection?; What was the diversity (e.g., ethnicity, age, diabetes type/duration) of the patient population in the training and validation datasets, and how might this affect its generalizability?; What are the cost-effectiveness implications of implementing IDx-DR in primary care compared to traditional referral pathways to ophthalmologists?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via De Novo pathway; IEC 62304 Class A (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
IDx-DR - IDx, LLC | ESL FDA AI Device Intelligence