Masimo SafetyNet
Masimo Corporation • Anesthesiology • 03/31/2023
Device Purpose
Masimo SafetyNet aims to enhance patient safety during opioid administration by continuously monitoring oxygen saturation and pulse rate via a wearable pulse oximeter, utilizing a pattern-recognition algorithm to detect sustained desaturations indicative of respiratory depression. This scientific approach enables the system to alert caregivers to potential opioid-induced respiratory events, thereby facilitating early intervention and reducing the incidence of unrecognized hypoxia.
Summary
Masimo SafetyNet is a remote patient monitoring system specifically engineered to enhance the safety of patients receiving opioid therapy by detecting early signs of respiratory depression. The system employs a wearable Rainbow SET™ pulse oximeter that continuously tracks a patient's oxygen saturation (SpO₂) and pulse rate for up to 15 days, making it suitable for both hospital and home care environments. Its core science lies in a sophisticated pattern-recognition algorithm designed to identify sustained decreases in oxygen saturation, which are critical indicators of opioid-induced respiratory compromise, thereby triggering alerts to caregivers. By focusing on trends in oxygenation rather than isolated threshold breaches, Masimo SafetyNet offers a more nuanced and potentially more accurate detection of adverse respiratory events. Clinical studies have substantiated its efficacy, demonstrating an improvement in the identification of such events and a corresponding reduction in unrecognized hypoxic episodes. As an adjunctive monitoring tool, it provides an additional layer of surveillance, aiming to facilitate timely interventions and mitigate risks associated with opioid use, ultimately contributing to improved patient outcomes during therapy.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the pattern-recognition algorithm in Masimo SafetyNet differentiate between transient desaturations and clinically significant opioid-induced respiratory depression, and what is its specificity and sensitivity in diverse patient populations (e.g., pediatric, geriatric, varying BMI)?; What is the typical response time from the detection of a sustained decrease in SpO₂ by the Masimo SafetyNet system to the caregiver being alerted, and how might this vary in different care settings (e.g., hospital ward density, home Wi-Fi reliability)?; Are there any identified patient characteristics or co-morbidities (e.g., pre-existing sleep apnea, COPD, concurrent sedative use) that might affect the accuracy or reliability of the Rainbow SET™ pulse oximeter and the pattern-recognition algorithm in the Masimo SafetyNet system, and are there specific calibration or alert threshold adjustments recommended for these cases?; Beyond reducing unrecognized hypoxic episodes, what are the documented downstream impacts of Masimo SafetyNet implementation on clinical workflows, healthcare resource utilization (e.g., rapid response team activations, length of hospital stay), and overall patient outcomes, including patient-reported comfort and anxiety levels?; What are the data security and privacy measures implemented within the Masimo SafetyNet system, particularly when used in home environments, and how does it integrate with existing electronic health record (EHR) systems for seamless data flow and documentation?
Risk Classification
ESL AnalysisFDA Class II via De Novo pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly