Medscape Medical NewsAll articles

Gili Pro BioSensor (also known as “Gili BioSensor System”)

ContinUse Biometrics Ltd. • Cardiovascular • 04/01/2021

De NovoIEC 62304 Class C
FDA Summary PDF

Device Purpose

The Gili Pro BioSensor offers a contactless method for monitoring heart rate and respiratory rate by using near-infrared light to sense chest wall vibrations. Clinical trials have validated its accuracy as comparable to traditional devices, establishing it as a hygienic and non-invasive alternative for spot-check vital sign assessments.

Summary

The Gili Pro BioSensor is an innovative contactless device engineered for monitoring critical vital signs, specifically heart rate and respiratory rate. Its core methodology involves emitting near-infrared light towards a patient, who can be either seated or lying down, and then detecting the subtle vibrations of the chest wall induced by cardiopulmonary activity; these measurements are subsequently displayed on a monitor for convenient spot-check assessments by healthcare professionals without requiring any physical patient contact. Clinical validation studies have affirmed the Gili Pro BioSensor's efficacy and accuracy, demonstrating performance comparable to established traditional methods like finger-clip pulse oximeters and chest-strap monitors. Notably, the device maintained its reliability even when used with subjects presenting challenging physiological conditions, such as arrhythmias or high Body Mass Indexes (BMI), consistently staying within acceptable margins of error, positioning it as a hygienic and non-invasive alternative for vital signs monitoring.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Gili Pro BioSensorcontactlessvital signsnear-infrared lightchest wall vibrationsheart raterespiratory rateclinical trialsaccuracynon-invasive

Device Metadata

Submission Number
DEN200038
Company
ContinUse Biometrics Ltd.
Panel
Cardiovascular
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the Gili Pro BioSensor differentiate between chest wall vibrations caused by cardiac activity versus respiratory activity or other patient movements?; What is the optimal operational distance and angular range for the Gili Pro BioSensor, and how is its accuracy affected by variations in patient positioning or clothing?; Were specific types of arrhythmias evaluated in the clinical trials, and did the device's accuracy vary among them?; What are the 'acceptable error margins' mentioned in comparison to traditional devices, and how were these determined?; Are there plans to expand the Gili Pro BioSensor's capabilities beyond spot-check assessments to include continuous monitoring or data logging?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via De Novo pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials(remote)
✓ Detected
HBOMHardware Bill of Materials(sensor)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(operational)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SaaSBOM, HBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, ML-BOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Gili Pro BioSensor (also known as “Gili BioSensor System”) - ContinUse Biometrics Ltd. | ESL FDA AI Device Intelligence