16 Bit Inc • Radiology • 04/09/2024

De NovoIEC 62304 Class B
FDA Summary PDF

Device Purpose

Rho is an AI-powered software tool designed for opportunistic osteoporosis screening by analyzing routine radiographs in patients aged 50 and older to estimate bone mineral density at the lumbar spine and femoral neck. Utilizing a random forest ensemble model trained on DXA-correlated data, it flags likely low bone density cases to prompt further evaluation and facilitate early intervention.

Summary

Rho is an innovative software tool developed for opportunistic osteoporosis screening in individuals aged 50 and older. It leverages an artificial intelligence model that analyzes existing routine radiographs, such as chest, abdominal, or pelvic X-rays, incorporating patient-specific data like age and sex. The primary function of Rho is to estimate bone mineral density (BMD) at critical skeletal sites, specifically the lumbar spine and femoral neck. Upon identifying cases with a high likelihood of low bone mineral density, the system automatically flags these instances within the radiology Picture Archiving and Communication System (PACS). This alert prompts clinicians to consider further, more definitive diagnostic procedures, most notably Dual-energy X-ray absorptiometry (DXA) scanning, to confirm the diagnosis. The underlying technology of Rho is a random forest ensemble AI model, which was meticulously trained and validated using multi-center patient cohorts where DXA results were already known. The performance of this model is characterized by high specificity, ranging from approximately 90% to 93%, indicating a low rate of false positives. However, its sensitivity is moderate, reported between 36% and 67%, suggesting it may miss a portion of individuals with actual low BMD. By seamlessly integrating into established clinical workflows, Rho aims to enhance the identification of at-risk patients for osteoporosis who might otherwise go undetected, thereby improving the prospects for timely intervention and management of the condition.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Osteoporosis screeningBone mineral densityRadiographsAI modelRandom forestDXASpecificitySensitivityLumbar spineFemoral neck

Device Metadata

Submission Number
DEN230023
Company
16 Bit Inc
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the Rho AI model account for variations in radiographic image quality and patient positioning that could affect bone mineral density estimation accuracy?; What is the performance of Rho in diverse patient populations, particularly those with comorbidities or previous spinal/hip surgeries that might confound radiographic interpretation?; Given the moderate sensitivity (36-67%), what is the estimated number of missed cases of low bone mineral density when using Rho, and what are the potential clinical implications of these false negatives?; How does the automated flagging by Rho in the radiology PACS specifically impact radiologist workflow, reporting times, and the rate of subsequent DXA scan recommendations?; What longitudinal studies have been conducted or are planned to assess the long-term clinical impact of Rho implementation on osteoporosis diagnosis rates, initiation of treatment, and patient outcomes, such as fracture prevention?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via De Novo pathway; IEC 62304 Class B (software safety classification); Post-§524B but no clear network capability detected

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score0/100
SBOM Evidence⚠ Not in summary - likely in full submission per §524B
Cyber Risk Assessment⚠ Not in summary - likely in full submission per §524B
Postmarket Plan⚠ Not in summary - likely in full submission per §524B
§524B ApplicableYes

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.

• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, ML-BOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Rho - 16 Bit Inc | ESL FDA AI Device Intelligence