Sleep Apnea Feature
Samsung Electronics Co., Ltd • Anesthesiology • 02/06/2024
Device Purpose
Samsung's Sleep Apnea Feature for Galaxy smartwatches employs PPG-based SpO₂ and pulse monitoring over two nights, utilizing an embedded AI pipeline to estimate an apnea-hypopnea index (eAHI) for screening adults for moderate-to-severe obstructive sleep apnea. This over-the-counter technology aims to broaden accessibility to initial sleep apnea risk detection, alerting users with significantly elevated eAHI readings to consult healthcare professionals.
Summary
Samsung's Sleep Apnea Feature, integrated into Galaxy smartwatches, is designed as an over-the-counter screening tool for adults aged 22 and older to detect signs of moderate-to-severe obstructive sleep apnea. The system leverages photoplethysmography (PPG) sensors to continuously monitor the user's pulse and blood oxygen saturation (SpO₂) levels over two separate nights of sleep. This collected physiological data is then processed by an embedded artificial intelligence (AI) pipeline specifically developed to analyze these signals. The AI algorithm preprocesses the PPG and SpO₂ data to estimate an apnea-hypopnea index (eAHI), which quantifies the number of apnea and hypopnea events per hour of sleep. If this estimated AHI is consistently 15 events per hour or higher across both monitored nights, the feature alerts the user, recommending they seek a formal medical evaluation for sleep apnea. The development of this algorithm was informed by data from over 1,000 subjects, with its performance benchmarked against polysomnography results, demonstrating high accuracy with up to 100% sensitivity and 94.1% specificity, even in conditions of low peripheral perfusion, meeting established accuracy standards for such screening tools.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the AI pipeline specifically differentiate between obstructive sleep apnea events and other respiratory disturbances or signal artifacts using only PPG-based SpO₂ and pulse data?; What is the long-term reliability and performance of the PPG sensor and AI algorithm across diverse populations with varying skin tones, wrist sizes, and comorbid conditions not extensively covered in the initial 1,000-subject study?; What is the positive predictive value and negative predictive value of an eAHI above 15 events/hour in a general population, considering the prevalence of moderate-to-severe OSA?; How does the device's performance in detecting sleep apnea compare when users engage in activities or sleep in positions that might compromise PPG signal quality (e.g., wrist flexion, pressure on the watch)?; What are the defined thresholds and mechanisms within the AI for determining 'low perfusion conditions,' and how does the algorithm adjust or maintain accuracy under such circumstances?
Risk Classification
ESL AnalysisFDA Class II via De Novo pathway; IEC 62304 Class C (software safety classification); Post-§524B but no clear network capability detected
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, HBOM detected in AI-generated device summary.
• SBOM not mentioned in AI-generated device summary. Under §524B (effective Oct 2023), cyber devices must provide a SBOM.
• Cybersecurity risk assessment not referenced in AI-generated device summary. FDA cybersecurity guidance (2023) expects this for cyber devices.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly