Medscape Medical NewsAll articles

EASYCELL CELL LOCATOR

MEDICA CORP. • Hematology • 05/12/2010

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The EasyCell is an automated in vitro diagnostic system that scans and analyzes peripheral blood smears to aid in hematological assessments. It employs image capture, mathematical algorithms, and artificial neural networks to locate, pre-classify white blood cells, and present images of red blood cells and platelets for operator review and evaluation.

Summary

The EasyCell is an automated cell-locating device designed for in vitro diagnostic use by skilled professionals. Its primary function is to locate and present digital images of white blood cells, red blood cells, and platelets from prepared peripheral blood smears. This system assists qualified technologists in conducting white blood cell (WBC) differential counts, evaluating red blood cell (RBC) morphology, and estimating platelet numbers, thereby streamlining and supporting manual review processes. The device operates by scanning Romanowsky-stained blood films on glass slides using a battlement track pattern to ensure comprehensive area coverage. Cell images are then analyzed using standard mathematical methods, critically incorporating deterministic artificial neural networks (ANNs) specifically trained to distinguish between different classes of white blood cells. The EasyCell pre-classifies WBCs, which are then reviewed, confirmed, or re-classified by the operator. For RBCs, it presents a series of images for morphological assessment, and for platelets, images are provided for operator estimation according to standardized procedures. Performance studies involving 304 patient samples demonstrated high correlation with traditional manual microscopy for WBC differentials (e.g., neutrophil r=0.99, lymphocyte r=0.98), overall sensitivity of 91% and specificity of 72% in identifying abnormalities, good agreement for platelet estimates, and over 90% agreement for RBC morphology assessment.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Automated Cell-LocatingPeripheral Blood SmearsWhite Blood Cell DifferentialRed Blood Cell MorphologyPlatelet EstimateArtificial Neural NetworksImage AnalysisHematologyIn Vitro DiagnosticRomanowsky Stain

Device Metadata

Submission Number
K092116
Company
MEDICA CORP.
Panel
Hematology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. How does the performance of the EasyCell's artificial neural network vary with challenging or rare cell morphologies not extensively represented in its training dataset?; What is the specific training methodology and dataset size used for the deterministic artificial neural networks in classifying white blood cells?; What are the quantitative limits of detection for abnormal cells (e.g., blast cells) and how does this compare to manual microscopy, particularly at low concentrations?; Could the EasyCell's image analysis capabilities be expanded to quantify other hematological parameters, such as reticulocyte counts or identify parasitic inclusions?; How does the 'battlement track pattern' for cell location optimize for both speed and representativeness of the entire blood smear compared to other scanning patterns?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, machine learning, neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
EASYCELL CELL LOCATOR - MEDICA CORP. | ESL FDA AI Device Intelligence