EASYCELL CELL LOCATOR
MEDICA CORP. • Hematology • 05/12/2010
Device Purpose
The EasyCell is an automated in vitro diagnostic system that scans and analyzes peripheral blood smears to aid in hematological assessments. It employs image capture, mathematical algorithms, and artificial neural networks to locate, pre-classify white blood cells, and present images of red blood cells and platelets for operator review and evaluation.
Summary
The EasyCell is an automated cell-locating device designed for in vitro diagnostic use by skilled professionals. Its primary function is to locate and present digital images of white blood cells, red blood cells, and platelets from prepared peripheral blood smears. This system assists qualified technologists in conducting white blood cell (WBC) differential counts, evaluating red blood cell (RBC) morphology, and estimating platelet numbers, thereby streamlining and supporting manual review processes. The device operates by scanning Romanowsky-stained blood films on glass slides using a battlement track pattern to ensure comprehensive area coverage. Cell images are then analyzed using standard mathematical methods, critically incorporating deterministic artificial neural networks (ANNs) specifically trained to distinguish between different classes of white blood cells. The EasyCell pre-classifies WBCs, which are then reviewed, confirmed, or re-classified by the operator. For RBCs, it presents a series of images for morphological assessment, and for platelets, images are provided for operator estimation according to standardized procedures. Performance studies involving 304 patient samples demonstrated high correlation with traditional manual microscopy for WBC differentials (e.g., neutrophil r=0.99, lymphocyte r=0.98), overall sensitivity of 91% and specificity of 72% in identifying abnormalities, good agreement for platelet estimates, and over 90% agreement for RBC morphology assessment.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the performance of the EasyCell's artificial neural network vary with challenging or rare cell morphologies not extensively represented in its training dataset?; What is the specific training methodology and dataset size used for the deterministic artificial neural networks in classifying white blood cells?; What are the quantitative limits of detection for abnormal cells (e.g., blast cells) and how does this compare to manual microscopy, particularly at low concentrations?; Could the EasyCell's image analysis capabilities be expanded to quantify other hematological parameters, such as reticulocyte counts or identify parasitic inclusions?; How does the 'battlement track pattern' for cell location optimize for both speed and representativeness of the entire blood smear compared to other scanning patterns?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly