Medscape Medical NewsAll articles

UNICEL DXH 800 COULTER CELLULAR ANALYSIS SYSTEM

BECKMAN COULTER, INC. • Hematology • 03/22/2013

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The UniCel DxH 800 COULTER Cellular Analysis System is an automated hematology analyzer for in vitro diagnostic screening in clinical laboratories, providing comprehensive analysis of whole blood and body fluids. It utilizes the Coulter Principle for cell counting and sizing, and VCSn technology for advanced differential, nucleated red blood cell, and reticulocyte characterization based on volume, conductivity, and light scatter measurements.

Summary

The UniCel® DxH 800 COULTER® Cellular Analysis System, featuring software version 2.0, is an automated, quantitative multi-parameter hematology analyzer designed for in vitro diagnostic use in clinical laboratories. Its primary function is to perform comprehensive hematological analysis, including complete blood counts (CBC), leukocyte differentials, nucleated red blood cell (NRBC) enumeration, and reticulocyte analysis on various sample types such as whole blood (venous and capillary, including pre-diluted forms). The system also extends its capabilities to enumerate Total Nucleated Cells (TNC) and Red Blood Cells (RBC) in body fluids like cerebrospinal, serous, and synovial fluids. It is intended to assist clinicians by differentiating patients with normal hematological profiles from those who may require additional diagnostic studies. The DxH 800 employs established scientific principles for its analyses. It utilizes the Coulter Principle, an electrical impedance-based method, for counting and sizing cells, where particles passing through an aperture generate electrical pulses proportional to their volume. Hemoglobin concentration is determined photometrically at 525 nm following red blood cell lysis. For detailed analysis of white blood cell differentials, NRBCs, and reticulocytes, the system incorporates COULTER® VCSn technology. This technology measures cell volume (V), conductivity (C), and light scatter (Sn) characteristics using a diode laser as cells pass through a flow cell. The system architecture includes a Specimen Processing Module (SPM) for automated sample handling, mixing, and reagent incubation; a System Manager (a PC-based workstation) for operational control, data processing, and results management; a Pneumatic Supply Module; and a suite of dedicated reagents, controls, and calibrators. It offers flexibility through various test panels and sampling methods, including automated cassette loading and manual single tube (open or closed vial) options.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Hematology analyzerAutomated cell counterCoulter PrincipleVCSn technologyComplete Blood Count (CBC)Leukocyte differentialReticulocyte analysisNucleated Red Blood Cells (NRBC)Body fluid analysisIn vitro diagnostic

Device Metadata

Submission Number
K120771
Company
BECKMAN COULTER, INC.
Panel
Hematology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What are the specific performance characteristics (e.g., accuracy, precision, linearity) of the UniCel DxH 800 for each reported parameter, particularly for samples with very low or high cell counts?; How does the VCSn technology specifically differentiate between the five white blood cell types and identify NRBCs, and what are its limitations when analyzing samples with atypical or immature cell populations?; What are the daily, weekly, and monthly maintenance requirements for the UniCel DxH 800 system, and how does software version 2.0 specifically enhance usability or error handling compared to previous versions?; What is the effective throughput of the analyzer (samples per hour) when processing common test panel combinations, such as CBC with differential and reticulocytes, including any associated sample preparation time?; How does the system detect and flag potential interferences from common substances like lipemia, icterus, or hemolysis, and what is the impact of these interferences on the accuracy of reported parameters?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score35/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software version)
✓ Detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cellular)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(operational)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: ML-BOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
UNICEL DXH 800 COULTER CELLULAR ANALYSIS SYSTEM - BECKMAN COULTER, INC. | ESL FDA AI Device Intelligence