Medscape Medical NewsAll articles

CLEARREAD +CONFIRM

RIVERAIN TECHNOLOGIES • Radiology • 12/27/2012

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

ClearRead +Confirm is a post-processing software application designed to facilitate the confirmation of line and tube placement in adult chest radiographs by generating an enhanced secondary image. It employs a bone suppression algorithm, with specific enhancements to improve line and tube visibility, thereby aiding trained professionals in localizing these devices more efficiently.

Summary

ClearRead +Confirm is a specialized post-processing software application designed to create an enhanced, secondary digital radiographic image of the chest. Its purpose is to assist trained medical professionals, such as physicians, radiologists, and technicians, in confirming the placement of lines and tubes in adult patients. The system employs a bone suppression algorithm, building upon the technology of a predicate device, ClearRead Bone Suppression, but with specific enhancements aimed at improving the visibility of these medical apparatuses. The enhanced AP or PA image produced serves as an adjunctive tool and is not intended to replace the original radiograph, nor is it intended for use on pediatric patients. The performance of ClearRead +Confirm was assessed through functional verification and a clinical validation study involving multiple readers and cases (MRMC). This clinical study focused on evaluating whether the software reduced the time radiologists spent localizing the tips of tubes, lines, and electrical cardiac wires (TLW), and also assessed localization accuracy compared to unaided image review. The findings demonstrated that ClearRead +Confirm significantly decreased the reading time required for TLW localization. While the accuracy of localization with the software was not found to be statistically significantly different from unaided reads, the overall results suggest it is a beneficial adjunct for interpreting chest radiographs when assessing TLW placement. The system shares a common DICOM communication platform with its bone suppression predicate and offers similar line/tube enhancement capabilities to another predicate device.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

ClearRead +ConfirmImage ProcessingChest RadiographLine ConfirmationTube ConfirmationBone SuppressionSecondary ImageRadiologistClinical ValidationDICOM

Device Metadata

Submission Number
K123526
Company
RIVERAIN TECHNOLOGIES
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. What is the specific nature of the "enhancements to improve the visibility of lines and tubes" beyond the foundational bone suppression, and how were these optimized during development?; The MRMC study showed significantly decreased read times; what was the mean reduction in time per reading, and was this reduction consistent across different types of lines/tubes or reader experience levels?; Given that localization accuracy was not statistically significantly different, what metrics or qualitative feedback, if any, indicated that ClearRead +Confirm is a "useful adjunct" beyond just speed?; How robust is the ClearRead +Confirm algorithm to variations in image quality or patient anatomical variations (e.g., obesity, severe lung pathology) that might affect chest radiograph interpretation?; What specific training protocol is recommended for professionals to effectively utilize ClearRead +Confirm, and how does the system guide users in distinguishing enhanced features from potential artifacts?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
CLEARREAD +CONFIRM - RIVERAIN TECHNOLOGIES | ESL FDA AI Device Intelligence