Medscape Medical NewsAll articles

HEPATIC VCAR

GE MEDICAL SYSTEMS SCS • Radiology • 04/22/2014

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Hepatic VCAR is a CT image analysis software package intended to aid clinicians in assessing liver morphology and lesions from DICOM 3.0 CT scans through automated segmentation and quantitative analysis. It utilizes advanced algorithms for 3D visualization, liver and lesion segmentation, vessel analysis, and features like a virtual scalpel, with user oversight for final contour adjustments.

Summary

Hepatic VCAR is a CT image analysis software package designed for the analysis and visualization of liver CT data obtained from DICOM 3.0 compliant CT scans. Its primary purpose is to assist clinicians in assessing liver morphology, including the identification and measurement of liver lesions, provided these lesions exhibit a different CT appearance from the surrounding liver tissue. The software facilitates tracking changes in liver morphology and lesions over time through automated tools for segmenting and measuring the liver, liver lobes, liver segments, and lesions. Key functionalities of Hepatic VCAR include lesion segmentation, liver segmentation, portal vein segmentation, separation of liver segments based on portal vein branches, and a 'Virtual Scalpel' feature. The software provides initial 3D segmentation, vessel analysis, visualization, and quantitative analysis of liver anatomy. Users retain the ability to manually adjust the automatically generated contours and confirm the final segmentation. Hepatic VCAR can be deployed as a standalone post-processing application on GE Healthcare's AW VolumeShare 5 workstation and AW Server image processing platforms.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Hepatic VCARCT image analysisLiver morphologyDICOM 3.0Lesion segmentationLiver segmentationPortal vein segmentation3D segmentationQuantitative analysisVirtual Scalpel

Device Metadata

Submission Number
K133649
Company
GE MEDICAL SYSTEMS SCS
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What is the quantitative accuracy and reproducibility of the automated liver and lesion segmentation algorithms compared to manual segmentation by expert radiologists across diverse patient populations and lesion types?; How does the 'Virtual Scalpel' feature account for anatomical variability and potential intraoperative changes when used for pre-surgical planning?; Are there specific CT acquisition parameters or contrast enhancement protocols recommended to optimize the performance of Hepatic VCAR's segmentation and analysis tools?; What is the minimum detectable change in lesion size or morphology over time that Hepatic VCAR can reliably quantify?; How does the software handle challenging cases, such as livers with diffuse disease, multiple closely spaced lesions, or images with significant artifacts?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score35/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software package)
✓ Detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly