Volpara Imaging Software
Matakina Technology LTD • Radiology • 01/07/2016
Device Purpose
Volpara Imaging Software utilizes raw digital breast x-ray and tomosynthesis data to generate quantitative density maps and calculate volumetric breast density, along with other metrics of tissue composition. This system provides objective measurements and BI-RADS categories as adjunctive information to aid clinicians in breast tissue assessment, supported by validation against phantoms, MRI data, and radiologist evaluations.
Summary
Volpara Imaging Software is an application designed to analyze raw data from digital breast x-ray systems, including tomosynthesis, to aid in breast tissue composition assessment. The software processes these images to generate detailed density maps, where each pixel value represents the thickness of fibroglandular tissue, and from these maps, it calculates volumetric breast density as a ratio of fibroglandular tissue volume to total breast volume, also providing additional quantitative metrics like average and maximum dense tissue thickness and maximum dense tissue volume over specific areas with their locations. The software outputs these numerical values, the density maps in DICOM SCI format for visualization, and an associated BI-RADS breast density category (4th or 5th Edition); its intended use is as adjunctive information for MQSA-qualified interpreting physicians, not as a standalone diagnostic tool. The system operates on a Windows server and has undergone extensive verification and validation, including accuracy testing against phantoms and MRI data, reproducibility assessments across different views, patient sides, imaging systems, and modalities (mammography vs. tomosynthesis), and comparison with radiologists' visual assessments, meeting all established criteria.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the software's algorithm differentiate between fibroglandular tissue and other breast tissues with varying x-ray attenuation, especially in tomosynthesis datasets?; What is the specific impact on clinical workflow and decision-making when integrating the additional quantitative statistics (e.g., max thickness of dense tissue) provided by version 1.5.2 compared to previous versions?; How does the software account for variations in image acquisition parameters (e.g., compression, exposure) across different mammography and tomosynthesis machines when calculating density maps and volumetric measurements?; What were the quantitative measures of agreement (e.g., Kappa statistic, correlation coefficients) between Volpara's BI-RADS categorization and those assigned by MQSA radiologists in the validation studies?; Beyond BI-RADS categorization, how might the detailed density maps and quantitative metrics for dense tissue distribution (e.g., location of maximum density) be utilized for personalized risk assessment or treatment planning?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly