Medscape Medical NewsAll articles

ClearRead CT

RIVERAIN TECHNOLOGIES, LLC • Radiology • 09/09/2016

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

ClearRead CT is a software application intended to improve radiologists' detection of pulmonary nodules in chest CT scans of asymptomatic individuals by generating a vessel-suppressed secondary image series with CADe markers. The system utilizes advanced image processing and machine learning algorithms for segmentation, vessel suppression, and nodule feature analysis to identify and characterize suspicious regions, thereby enhancing detection accuracy and reducing interpretation time.

Summary

ClearRead CT™, developed by Riverain Technologies, LLC, is a dedicated post-processing software application designed to assist radiologists in the detection of pulmonary nodules during the review of chest CT examinations from asymptomatic individuals. It functions as an adjunctive tool, creating a secondary, vessel-suppressed lung CT series with Computer-Aided Detection (CADe) marks and associated region descriptors for up to five Regions of Interest (ROIs) per scan; it is not intended as a substitute for the original CT series. The system receives the original lung CT series and applies advanced image analysis and machine learning algorithms through sequential steps: volume preparation, body and air segmentation, volume normalization for consistent image appearance, airway and lung segmentation, and a critical vessel suppression technique that removes vascular structures, bronchial walls, and fissure lines while aiming to preserve nodular structures, including those attached to vasculature, thereby enhancing nodule detectability. The core science involves ROI generation from the vessel-suppressed volume, followed by feature extraction—computing measurements such as volume, maximum/minimum diameter, and average density for each ROI—and ROI classification, which includes rejecting calcified nodules and limiting marks to the top five ranked ROIs. ClearRead CT is optimized for detecting solid, sub-solid, and ground glass nodules primarily between 5mm and 30mm. Clinical validation via a multi-reader multi-case (MRMC) study demonstrated significant improvements in radiologist performance; the partial area under the Localization Receiver Operating Characteristic (LROC) curve for detecting actionable nodules increased from 0.6786 (unaided) to 0.7469 (aided with ClearRead CT), a statistically significant improvement (p=0.0418). Furthermore, the use of ClearRead CT resulted in a statistically significant 26% reduction in radiologists' interpretation time, averaging a decrease of 29 seconds per case. Standalone machine performance testing on clinical data showed a sensitivity of 89.5% for detecting cancers at a false positive rate of 0.7469 per case.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Pulmonary nodulesComputed Tomography (CT)Computer-Aided Detection (CADe)Vessel suppressionImage processingRadiologyLung cancer screeningAsymptomatic populationNodule characterizationLocalization Receiver Operating Characteristic (LROC)

Device Metadata

Submission Number
K161201
Company
RIVERAIN TECHNOLOGIES, LLC
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. How does the vessel suppression algorithm differentiate between vascular structures and nodules, particularly for nodules attached to or abutting vessels?; What was the inter-reader variability in nodule detection and characterization both with and without the ClearRead CT, and how did the software impact this variability beyond the LROC curve improvement?; The system marks up to 5 Regions of Interest (ROIs) per CT series; what is the rationale for this limit, and how does the system prioritize which ROIs to mark if more than five suspicious regions are detected?; Given the system is optimized for detecting solid, sub-solid, and ground glass nodules between 5mm and 30mm, what is its performance on nodules outside this size range or of different morphologies?; The clinical study data included CT scans with slice thicknesses of 2-3.0mm; how does the performance of ClearRead CT vary with different CT acquisition parameters, such as thinner slices or varying radiation doses and reconstruction kernels?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, feature extraction)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
ClearRead CT - RIVERAIN TECHNOLOGIES, LLC | ESL FDA AI Device Intelligence