PixelShine
ALGOMEDICA • Radiology • 09/19/2016
Device Purpose
PixelShine is a software application intended to enhance CT image quality for improved diagnostic assessment by utilizing a non-linear filter to reduce image noise. The system processes DICOM CT images on a standard PC, integrating into existing network environments to provide clearer images for radiological review, with its performance validated through phantom-based testing.
Summary
PixelShine is a medical imaging software application designed to process and enhance computed tomography (CT) images in DICOM format. It operates on a standard personal computer within a user's network, functioning to receive CT images, apply a noise reduction algorithm, and then transfer the processed images. The primary goal is to improve image quality by reducing noise, thereby aiding radiologists and other medical specialists in their diagnostic interpretation of CT scans. The core technology of PixelShine utilizes a non-linear filter to achieve noise reduction in the original CT images. The system is designed to operate independently, processing images and making both the original and enhanced versions available, typically for viewing on a workstation and storage on a PACS system. The device's performance in enhancing image quality has been validated through non-clinical tests involving phantoms and comparative analysis of image data. However, the image processing is not effective for lesions, masses, or abnormalities smaller than 3 mm and is not intended for use with mammography images.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the non-linear filter in PixelShine specifically differentiate between noise and subtle image details, particularly near the 3mm resolution limit?; What is the quantitative impact of PixelShine processing on common image quality metrics (e.g., SNR, CNR) across various CT scanner types and low-dose protocols?; Are there specific CT acquisition parameters or patient characteristics that might affect the performance or efficacy of the PixelShine noise reduction algorithm?; What is the typical processing latency introduced by PixelShine per CT series, and how does this integrate into high-throughput radiology workflows?; Beyond general noise reduction, how does PixelShine handle or potentially affect the appearance of different types of CT artifacts (e.g., beam hardening, motion artifacts)?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.