Medscape Medical NewsAll articles

FFRct

HEARTFLOW, INC. • Cardiovascular • 08/24/2016

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

FFRct v2.0 is a software device that provides a non-invasive method for the functional assessment of coronary artery disease by analyzing patient-specific CT data to simulate coronary blood flow and derive fractional flow reserve values. Its methodology involves creating a 3D model of the coronary arteries from static CT images and applying computational fluid dynamics principles to calculate FFRct, aiming to improve diagnostic accuracy for hemodynamically significant stenoses compared to anatomical assessment with cCTA alone.

Summary

FFRct v2.0 is a coronary physiologic simulation software designed for the clinical quantitative and qualitative analysis of coronary artery disease (CAD) in clinically stable symptomatic patients. It utilizes previously acquired Computed Tomography (CT) DICOM data to generate a 3D computer model of the coronary arteries. From this model, the software simulates pressure, velocity, and blood flow, mathematically deriving a quantity known as FFRct. This FFRct value is intended to support the functional evaluation of CAD, providing clinicians with insights into the hemodynamic significance of coronary artery obstructions to aid in their assessment and evaluation alongside other clinical information. Clinical validation for FFRct v2.0, utilizing data from the HeartFlowNXT study, demonstrated robust diagnostic performance. In per-vessel analysis against invasive Fractional Flow Reserve (FFR ≤ 0.80 as the reference standard for disease), FFRct achieved a sensitivity of 84.2% and a specificity of 84.9%. On a per-subject basis, when compared to site-read coronary CT angiography (cCTA using >50% stenosis criteria) with invasive FFR as the reference, FFRct showed superior diagnostic accuracy (80.0% for FFRct vs. 51.9% for cCTA) and notably higher specificity (76.4% for FFRct vs. 32.9% for cCTA). These findings suggest that FFRct offers an enhanced functional assessment over anatomical cCTA alone, potentially improving the identification of hemodynamically significant lesions non-invasively.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

FFRctCoronary Artery DiseasePhysiologic SimulationComputed TomographyDICOMHemodynamic AssessmentNon-invasive DiagnosisFractional Flow ReserveDiagnostic Accuracy3D Computer Model

Device Metadata

Submission Number
K161772
Company
HEARTFLOW, INC.
Panel
Cardiovascular
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of FFRct v2.0 vary across different CT scanner manufacturers and imaging protocols beyond those included in the HeartFlowNXT validation dataset?; What is the quantitative impact of varying levels of CT image quality (e.g., noise, artifacts, calcification) on the accuracy and reliability of the FFRct calculations?; What is the learning curve for clinicians to effectively interpret FFRct results and integrate them into their decision-making process, particularly in complex anatomical scenarios?; How does FFRct performance compare in specific challenging patient subgroups, such as those with prior coronary artery bypass grafts, in-stent restenosis, or diffuse coronary artery disease?; Are there planned or ongoing studies to evaluate the long-term clinical outcomes and cost-effectiveness of incorporating FFRct analysis into standard diagnostic pathways for suspected coronary artery disease?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
FFRct - HEARTFLOW, INC. | ESL FDA AI Device Intelligence