Medscape Medical NewsAll articles

ClearView cCAD

ClearView Diagnostics Inc. • Radiology • 12/28/2016

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

ClearView cCAD is an image analysis software designed to assist physicians by automatically classifying shape and orientation characteristics of selected regions in breast ultrasound images using multivariate pattern recognition. The system operates as a web service, processing DICOM images and leveraging novel descriptors to support ACR BI-RADS assessment, with its performance in discerning these parameters demonstrated to be statistically equivalent to experienced radiologists in non-clinical testing.

Summary

ClearView cCAD is a software application designed to assist skilled physicians in the analysis of breast ultrasound images. It functions by automatically classifying the shape and orientation characteristics of user-selected regions of interest (ROIs), employing multivariate pattern recognition methods and novel statistical, texture, shape, and orientation descriptors to characterize lesions from DICOM compliant digital medical files queried from ultrasound devices or PACS servers. Users select an ROI, and the software analyzes it, displaying results for automated reporting, storage, or modification, thereby aiding compliance with the ACR BI-RADS® ultrasound lexicon classification form. Operating as a platform-agnostic web service compatible with Windows 7 or higher systems, ClearView cCAD notably does not perform automatic lesion segmentation, a step deemed unnecessary for its classification accuracy when compared to predicate devices. Its web-based client architecture, distinct from standalone applications, includes mitigations to ensure image analysis occurs on original full-resolution images. Non-clinical bench testing, involving over 1200 cases evaluated against three MQSA certified radiologists, demonstrated that ClearView cCAD achieved overall accuracy for BI-RADS based shape and orientation assessment statistically equivalent to the radiologists.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Breast ultrasoundImage analysis softwareRegion of Interest (ROI)Shape classificationOrientation classificationMultivariate pattern recognitionDICOMACR BI-RADSLesion characteristicsWeb service

Device Metadata

Submission Number
K161959
Company
ClearView Diagnostics Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How do the 'novel statistical, texture, shape, and orientation descriptors' used by ClearView cCAD differ from standard image analysis algorithms, and what is their specific contribution to its performance in BI-RADS classification?; Given that the system does not perform automatic lesion segmentation, what are the potential implications for workflow efficiency and inter-observer variability in ROI selection by different users?; What specific 'mitigations were taken to ensure that all image analysis was performed on the original full resolution images' for the web-based client, and how does this address potential concerns about image fidelity compared to standalone applications?; The non-clinical performance data showed statistical equivalence to radiologists; were there specific types of lesions or BI-RADS categories where the software performed exceptionally well or where its performance was less aligned, and what might account for these variations?; How does the system handle images with poor quality or significant artifacts, and does its performance degrade predictably in such scenarios when assessing lesion characteristics?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(web service, server, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
ClearView cCAD - ClearView Diagnostics Inc. | ESL FDA AI Device Intelligence