Surgical Information Sciences, Inc. • Radiology • 02/14/2017

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

SIS Software is an application designed to enhance neurosurgical planning by using machine learning and a 7T MRI reference database to create patient-specific 3D models of the subthalamic nuclei from standard clinical MRI scans. Its methodology aims to improve visualization accuracy for STN targeting in procedures like stereotactic surgery, offering a significant improvement over standard visualization techniques.

Summary

SIS Software is a medical imaging application intended for viewing, presentation, and documentation of medical images, featuring modules for image processing, image fusion, and intraoperative functional planning. It is specifically designed to assist medical professionals, including surgeons, neurologists, and radiologists, by enhancing the visualization of the subthalamic nuclei (STN), providing a 3D output that can be utilized with stereotactic image-guided surgery systems or other devices for further processing. The software employs machine learning and image processing techniques to improve standard clinical MR images (1.5T or 3T). It leverages a reference database composed of high-resolution 7T MRI scans—where deep brain structures like the STN are more clearly discernible—to accurately identify and model these structures on a patient's lower-resolution clinical images, thereby generating a patient-specific 3D anatomical model of the brain. The performance of SIS Software was validated through rigorous testing. Developmental testing, using a leave-one-out statistical method on 10 subject datasets, demonstrated an average prediction accuracy of 1mm for the STN, which was significantly better than standard atlas methods. Pivotal validation testing was conducted on images from 34 subjects (68 STNs), using a dataset entirely independent of the one used for algorithm development. This validation assessed metrics such as center of mass distance, surface distance, and Dice coefficient. The results showed that 95% of center of mass distances and 100% of surface distances were not greater than 2.0mm, successfully meeting pre-specified accuracy criteria and significantly outperforming estimated standard-of-care visualization success rates (p<0.0001). The Dice coefficient recorded was 0.64, a value considered acceptable given the small size of the STN. These findings confirm that the SIS Software performs as intended, offering a clinically significant improvement in STN visualization for neurosurgical planning.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

SIS SoftwareSubthalamic Nuclei (STN)Medical ImagingMachine LearningImage Processing7T MRIStereotactic SurgeryNeurosurgical Planning3D Anatomical ModelImage Fusion

Device Metadata

Submission Number
K162830
Company
Surgical Information Sciences, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the SIS Software's machine learning algorithm adapt to anatomical variability in the STN across different patient populations (e.g., age, pathology)?; What is the typical processing time required by the SIS Software to generate the patient-specific 3D model from clinical MRI data, and how might this impact intraoperative workflow?; Could the methodology of using a 7T MRI reference database be expanded to improve visualization of other deep brain structures beyond the STN that are poorly resolved on standard clinical MRI?; What are the specific limitations or contraindications for using SIS Software, particularly concerning image quality prerequisites for the input clinical MRI scans?; How does the performance of SIS Software compare, in terms of STN localization accuracy and clinical utility, to other advanced imaging techniques or manual segmentation methods employed by experienced neuroradiologists?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
SIS Software - Surgical Information Sciences, Inc. | ESL FDA AI Device Intelligence