Quantra

HOLOGIC, INC. • Radiology • 10/20/2017

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Quantra™ version 2.2 is a software application designed to aid radiologists in assessing breast tissue composition from digital mammograms by categorizing breast density according to BI-RADS® standards. Its methodology involves analyzing the distribution and texture of parenchymal tissue patterns, an improvement aimed at aligning with the ACR BI-RADS® Atlas (Fifth Edition, 2013) and enhancing estimation accuracy for breast composition.

Summary

Quantra™ version 2.2 is a software application designed to assist radiologists in the assessment of breast tissue composition using mammographic images acquired from digital breast x-ray systems. Its primary purpose is to segregate breast density into categories, aiding consistent reporting of BI-RADS® breast composition categories as mandated by certain state regulations, and it reports a result for each subject to assist radiologists. The software analyzes the distribution and texture of parenchymal tissue patterns within these images to estimate breast composition, providing adjunctive information and is not a diagnostic aid. The underlying science of Quantra 2.2 addresses the challenge that fibroglandular, or dense, tissue can obscure or mask abnormal lesions on a mammogram. This version incorporates algorithmic improvements to align with the ACR BI-RADS® Atlas (Fifth Edition, 2013) and enhance breast composition estimation accuracy by focusing on the distribution of glandular tissue rather than solely its density. Non-clinical testing using 230 retrospectively collected 4-view screening negative cases, compared against a five-radiologist consensus for BI-RADS 5th Edition categories, showed high accuracy: for 2D images, 92.9% for fatty (a+b) and 99.1% for dense (c+d) categories; for Tomo (3D center projection) images, 92.0% for fatty and 94.0% for dense categories.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

QuantraBreast DensityMammographyBI-RADSImage Analysis SoftwareFibroglandular TissueParenchymal TextureRadiologyBreast Composition AssessmentMasking Effect

Device Metadata

Submission Number
K163623
Company
HOLOGIC, INC.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does Quantra's algorithm specifically quantify the "distribution and texture of parenchymal tissue patterns" to differentiate BI-RADS categories, and how has this changed from version 2.1 which calculated volumetric/area density?; What were the specific criteria for the 5 radiologists' consensus in the non-clinical testing, particularly for borderline cases, and what was the inter-observer variability before consensus?; Given the accuracy differences between 2D (99.1% for dense) and Tomo (94.0% for dense) assessments, what specific image characteristics or algorithmic challenges in 3D data contribute to this, and are there plans to address this?; How does Quantra 2.2 ensure robustness and consistent performance across various digital mammography systems and image acquisition protocols, especially concerning the analysis of tissue texture?; The device is "not a diagnostic aid." What further research or features would be needed for Quantra to potentially evolve into a tool that could directly assist in diagnostic decisions related to lesion detection in dense breasts?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Quantra - HOLOGIC, INC. | ESL FDA AI Device Intelligence