UNiD Spine Analyzer
MEDICREA INTERNATIONAL • Radiology • 05/24/2017
Device Purpose
The UNiD Spine Analyzer is a web-based medical imaging software designed to assist healthcare professionals with image-based measurements and pre-operative planning for spinal surgeries, including osteotomies and the templating of patient-specific implants. Its methodology relies on digital image analysis and interactive surgical simulation tools, with performance validation demonstrating high measurement accuracy (e.g., mean distance error of 0.23mm, mean angular errors between 0.2° and 0.4°) when compared to existing systems.
Summary
The UNiD Spine Analyzer is a web-based software solution developed for the medical community, specifically healthcare professionals and surgeons, to aid in the viewing and measurement of medical images for planning orthopedic spinal surgeries. It supports standard image formats (jpeg, png, gif) and enables users to perform generic and spine-specific measurements, plan procedures like osteotomies, and template implants such as screws, cages, and patient-specific rods which can be ordered from MEDICREA. The surgical planning can either be a service provided by MEDICREA, requiring surgeon validation, or performed directly by the surgeon, offering flexibility in its application. The system operates by providing tools for overlaying measurements and surgical plans onto medical images, necessitating human intervention for image interpretation and manipulation. Its performance was evaluated through non-clinical testing, including software verification, validation, and cybersecurity assessments. Comparative tests against the Surgimap 2.0 system for basic measurements yielded high precision, with a mean distance error of 0.23mm (Standard Deviation 0.42mm) and a mean angle error of 0.2° (SD 0.4°). For surgical planning tools, such as those for wedge osteotomies and cage placement, the mean errors were similarly low at 0.25° (SD 0.44°) and 0.4° (SD 0.5°) respectively, underscoring its accuracy in simulating surgical interventions.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. Considering the reported mean errors in measurements (e.g., 0.23mm for distance, 0.2° for angles), what is the clinically acceptable tolerance for such pre-operative planning tools, and how do these errors potentially impact surgical outcomes or implant fit?; The system facilitates patient-specific rod manufacturing based on its plans. What is the detailed end-to-end workflow and quality control process from software-based planning to the physical manufacturing and delivery of these custom implants, particularly concerning the fidelity of translating digital plans to tangible devices?; Given that "Human Intervention for interpretation and manipulation of images [is] Required," what specific level of expertise or training is recommended for surgeons to effectively utilize the UNiD Spine Analyzer for complex surgical planning, and does the software incorporate any guidance or error-checking mechanisms to minimize user-dependent variability?; How does the UNiD Spine Analyzer accommodate variations in medical image quality stemming from different acquisition modalities or healthcare institutions, and does it feature any image pre-processing capabilities to normalize or enhance images for optimal measurement and planning accuracy?; While the UNiD Spine Analyzer supports custom implant templating, especially for patient-specific rods, what are the potential limitations regarding the complexity of spinal deformities or the types of surgical procedures for which this software is optimally suited, and what are the known challenging scenarios or failure modes?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, ML-BOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.