SOZO
ImpediMed Limited • Cardiovascular • 08/11/2017
Device Purpose
The SOZO™ system is a non-invasive bioimpedance spectroscopy device designed to quantify extracellular fluid differences between limbs by measuring electrical impedance across a range of frequencies. It aids clinicians in the assessment of unilateral lymphedema in at-risk adult patients by providing an L-Dex® ratio, an objective measure reflecting these fluid imbalances.
Summary
The SOZO™ system by ImpediMed Limited is a bioimpedance spectroscopy device designed to aid clinicians in assessing unilateral lymphedema in adult patients who have undergone lymph node removal, damage, or irradiation in the axillary or pelvic regions. Its methodology involves the patient making direct contact with stainless steel electrodes on a connected hand and footplate. Over approximately 30 seconds, the system applies a low-level electrical current (200 μA RMS) across a wide range of 256 frequencies (3kHz to 1000kHz), measuring current, voltage, and phase angle to calculate bioimpedance parameters, which are then used to estimate extracellular fluid levels in the limbs. The core output of the SOZO system is an L-Dex® ratio, derived from the impedance ratios between the left and right limbs, quantifying extracellular fluid volume differences to assess unilateral lymphedema of the arm and leg in women, and the leg in men. This L-Dex score is presented to the clinician on a scale to assist in their clinical assessment. The system includes an Android tablet with the "SOZOapp" for controlling the hardware via Bluetooth and transmitting measurement data via Wi-Fi to the "SOZOhub," PC software for data uploading, processing, and analysis. Performance testing confirmed electrical safety, biocompatibility, software validity, and functional reliability, with comparative studies against its predicate (L-Dex® U400) showing strong correlation (r > 0.99) in L-Dex readings.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the L-Dex ratio correlate with established clinical lymphedema staging systems, and what is the sensitivity and specificity of the SOZO device in detecting early-stage lymphedema compared to other diagnostic modalities?; What is the inter-operator and intra-operator variability of L-Dex measurements using the SOZO system, and what factors (e.g., patient positioning, hydration status) most significantly influence measurement accuracy?; Are there specific patient populations (e.g., those with comorbidities like congestive heart failure or renal disease) where the interpretation of L-Dex scores might be confounded or require adjustment?; How does the range of 256 frequencies (3kHz to 1000kHz) used by SOZO optimize the differentiation of extracellular fluid, and are there particular frequency sub-ranges that contribute most significantly to the L-Dex calculation?; Beyond unilateral lymphedema, what other potential clinical applications could leverage SOZO's bioimpedance spectroscopy technology for assessing fluid status or body composition, given its measurement capabilities?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of SaaSBOM, HBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Not detected in AI-generated device summary: SBOM, ML-BOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly