BladderScan Prime PLUS System
Verathon Incorporated • Radiology • 09/15/2017
Device Purpose
The BladderScan® PRIME PLUS system is a non-invasive diagnostic ultrasound device designed to accurately measure urinary bladder volume using B-mode imaging enhanced by patented neural network technology. It aims to provide clinicians with reliable bladder volume data for male, female, and pediatric patients through a portable system with a simplified user interface and no routine calibration requirement.
Summary
The BladderScan® PRIME PLUS system is a diagnostic ultrasound device designed for the non-invasive measurement of urinary bladder volume. It utilizes B-mode ultrasonic pulsed echo imaging and patented neural network technology to calculate bladder volume based on a complex, multifaceted image of the bladder. The system features a mechanical sector probe with a 13mm diameter, operating at nominal acoustic output frequencies of 2.49 / 1.72 MHz, a resonant frequency of 2.95 MHz, a 120-degree sector angle, and 12 scan planes. Key information such as bladder volume, directional aiming with real-time feedback, and system status is displayed on an LCD screen. The portable device operates on a lithium-ion battery and includes a charging cradle, along with accessories like a printer and mobile cart. The system is intended for use by physicians or medical professionals on male, female, and pediatric patients for abdominal B-mode imaging of the bladder, with a measurement range of 0 to 999 mL. It reports a measurement accuracy of ±7.5 mL for volumes between 0-100mL, and an accuracy of "± 7.5% ± 15% ± 15mL" for volumes between 100-999mL. Technological advancements include a simplified single mode of operation accommodating male, female, and small child patient types, and no longer recommends annual calibration. Non-clinical testing confirmed its safety and performance, meeting standards for biocompatibility, electrical safety (AAMI/ANSI ES 60601-1, IEC 60601-2-37), electromagnetic compatibility (IEC 60601-1-2), and acoustic output (Maximum Mechanical Index 0.424, Maximum Thermal Index ≤ 1.0, ISPTA ≤ 1.0 mW/cm2, ISPPA ≤ 12.0 W/cm2). The device is contraindicated for fetal use, pregnant patients, patients with ascites, or those with open skin or wounds in the suprapubic region.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the "patented neural network technology" improve bladder volume calculation accuracy or robustness compared to conventional B-mode algorithms, especially in challenging patient anatomies (e.g., post-surgery, obesity)?; What is the specific breakdown or meaning of the measurement accuracy stated as "± 7.5% ± 15% ± 15mL" for the 100-999 mL range, and under what conditions does each component of this error margin apply?; Given the simplified single mode of operation for male/female/small child, how does the system account for anatomical differences (e.g., presence or absence of uterus in females, smaller bladder size in children) that previously required distinct mode selections?; What are the practical implications and supporting data for removing the annual calibration recommendation compared to the predicate device which required it?; Were any specific usability studies conducted to validate the effectiveness of the BladderScan® PRIME PLUS's simplified user interface in reducing user error and improving workflow efficiency in diverse clinical settings, beyond general compliance with usability standards?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.