Medscape Medical NewsAll articles

HealthCCS

Zebra Medical Vision Ltd. • Radiology • 06/13/2018

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

HealthCCS is a software tool designed to automatically quantify coronary artery calcification from cardiac CT scans using a voxel density threshold and a CNN-based probability assessment to calculate an Agatston-equivalent risk score. The system aims to provide a non-invasive method for physicians to assess cardiovascular risk, with performance validated by agreement with radiologist-derived ground truth and demonstrating good reproducibility.

Summary

HealthCCS is a non-invasive, automatic post-processing software tool designed to evaluate calcified plaques in the coronary arteries from pre-existing non-contrast, ECG-gated/triggered cardiac or chest CT scans for patients over 20 years old. Its primary purpose is to aid physicians in assessing the risk of coronary artery disease by identifying and quantifying coronary artery calcification. The software operates by first identifying calcification based on a voxel density exceeding a predefined threshold of 130 Hounsfield Units (HU). Subsequently, a Convolutional Neural Network (CNN)-based probability threshold is applied to ascertain the likelihood that the identified calcium is located within the coronary arterial distribution. The HealthCCS system then calculates a Coronary Artery Calcium score using the Agatston method, averaging scores from multiple series if present, to provide a single Agatston-equivalent score for the study. The HealthCCS device generates patient reports that include a 4-category Agatston-equivalent risk score, which physicians can use for further analysis and to guide treatment decisions, particularly noting that patient management for low scores (0-10) relies on physician judgment and may necessitate additional testing. Performance validation was conducted through a retrospective study involving 249 scans, comparing HealthCCS's risk categorization against a ground truth established by three radiologists using a reference PACS device. This study demonstrated an adequate overall agreement of 0.89 (95% CI: 0.85-0.92) and good reproducibility, with identical Agatston equivalent scores across three readings for 150 studies. The device was found to provide accurate calcium scoring, meeting requirements for accuracy, precision, and reproducibility.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Coronary Artery CalcificationAgatston ScoreCT ScanPost-processing SoftwareCardiovascular Risk AssessmentNon-invasiveCNN (Convolutional Neural Network)Voxel Density130HU ThresholdECG-Gated CT

Device Metadata

Submission Number
K172983
Company
Zebra Medical Vision Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of the CNN-based probability threshold in HealthCCS for localizing coronary calcium compare to manual or semi-automatic methods in terms of accuracy and inter-observer variability, especially in complex anatomies or low-quality scans?; What is the clinical impact of HealthCCS providing only a total Agatston-equivalent score versus predicate devices that offer per-artery calcium scores, particularly in guiding localized interventions or more detailed risk stratification?; The document mentions an average Agatston equivalent score if multiple series are present. What is the rationale and validation for averaging scores from different series, and how does this approach affect the final risk categorization compared to selecting a single representative series?; Given the reliance on physician judgment for scores 0-10, what specific guidance or data does HealthCCS provide to support clinicians in these borderline cases, and how does its performance compare to other tools in this low-score range?; How does the spatial threshold of 1.5 mm² used by HealthCCS, compared to 1 mm² in the predicate, affect the sensitivity and specificity of calcification detection, particularly for smaller plaques, and what was the justification for this difference?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, neural network, ground truth)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
HealthCCS - Zebra Medical Vision Ltd. | ESL FDA AI Device Intelligence