FibriCheck

Qompium nv • Cardiovascular • 09/28/2018

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

FibriCheck is a software-based medical device that enables patients to self-monitor for atrial fibrillation by using a mobile device's camera to capture photoplethysmography (PPG) signals, which reflect heart rhythm. Clinical evaluation demonstrates that this PPG-based analysis of blood volume changes provides diagnostic accuracy for atrial fibrillation detection (sensitivity 95.60%, specificity 96.55%) comparable to single-lead ECG-based monitoring methods.

Summary

FibriCheck is medical device software designed for individuals diagnosed with, or at risk of developing, atrial fibrillation to perform self-tests and monitor their heart rhythms intermittently. The technology operates by using the optical sensor of a mobile device, such as a smartphone camera, to collect photoplethysmogram (PPG) data, which reflects changes in blood volume. This PPG data is then analyzed by the FibriCheck software to identify heart rhythm conditions, with a specific emphasis on detecting atrial fibrillation. Users have the option to share their recordings with physicians or monitoring services, and a companion web application is available for healthcare professionals to manage patient information and review the collected FibriCheck data. The clinical efficacy of FibriCheck was assessed in a study involving 223 participants, of whom 100 had atrial fibrillation. In this study, FibriCheck's performance was benchmarked against a 12-lead ECG, considered the gold standard. The results indicated that FibriCheck achieved a sensitivity of 95.60%, specificity of 96.55%, a positive predictive value of 95.60%, a negative predictive value of 96.55%, and an overall accuracy of 96.14%. These performance metrics were found to be comparable to those of the reference device, Kardia (AliveCor), which utilizes a single-lead ECG technique and reported metrics in the same study including a sensitivity of 94.09% and specificity of 97.47%. FibriCheck's software complies with relevant medical device software standards, including those for software lifecycle processes and usability engineering, and is classified as having a 'moderate' level of concern and Safety Class B.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

FibriCheckAtrial FibrillationPhotoplethysmography (PPG)Self-testingHeart Rhythm MonitoringMobile ApplicationOptical SensingDiagnostic AccuracyKardiaClinical Performance

Device Metadata

Submission Number
K173872
Company
Qompium nv
Panel
Cardiovascular
Product Code
N/A
Data Type
Signals
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection/diagnosis

Relevant Clinical Questions

  • Q1. How does the FibriCheck algorithm differentiate atrial fibrillation from other common arrhythmias or signal noise using only photoplethysmography (PPG) data?; What are the specific patient characteristics (e.g., skin tone, peripheral circulation status, comorbidities) that might impact the accuracy and reliability of FibriCheck's PPG measurements?; How does the 60-second fixed recording duration of FibriCheck affect its sensitivity in detecting paroxysmal atrial fibrillation episodes, particularly those that are brief or infrequent, compared to devices with variable or longer recording capabilities?; What usability factors were identified during the IEC 62366-1 testing, and how might these influence real-world adherence and correct usage by the target patient population for self-testing?; Beyond diagnostic accuracy, what data exists on FibriCheck's impact on clinical outcomes, patient management, or healthcare utilization when integrated into routine atrial fibrillation monitoring?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials(sensor, camera)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, HBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
FibriCheck - Qompium nv | ESL FDA AI Device Intelligence