Aidoc Medical, Ltd. • Radiology • 08/01/2018

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

BriefCase is an artificial intelligence-powered software designed to analyze non-enhanced head CT images for the detection of Intracranial Hemorrhage, providing rapid notifications to radiologists to expedite triage. Its methodology involves a deep learning algorithm processing images in parallel to standard care, aiming to significantly reduce the time to radiologist review for critical findings.

Summary

BriefCase is a radiological computer-aided triage and notification software designed to assist in the analysis of non-enhanced head CT images. Its primary purpose is to help hospital networks and radiologists improve workflow triage by flagging and communicating suspected findings of Intracranial Hemorrhage (ICH). The system utilizes an artificial intelligence algorithm, specifically a deep learning model trained on medical images, to process DICOM images. These images are received, de-identified, and analyzed chronologically. The software operates through three modules: an Aidoc Hospital Server, an Aidoc Cloud Server, and an Aidoc Worklist Application installed on the radiologist's desktop. When suspected ICH is detected, the Worklist Application provides pop-up notifications, including patient identifiers and a compressed, non-diagnostic preview image, prompting earlier review of the full images in the PACS system. This process runs in parallel with the standard of care, without altering original images or removing cases from the existing queue. The performance of BriefCase was evaluated in a retrospective, multicenter study involving 198 non-contrast head CT cases. The software demonstrated high accuracy in identifying ICH, achieving a sensitivity of 93.6% and a specificity of 92.3%, both exceeding the predefined 80% performance goal. A key secondary endpoint measured the potential clinical benefit in worklist prioritization. For 59 true positive ICH cases, the mean time-to-notification by BriefCase was 4.5 minutes, significantly shorter than the mean standard of care time-to-exam-open of 72.6 minutes. This resulted in a statistically significant mean time saving of approximately 68.1 minutes, highlighting the device's capability to facilitate earlier attention to critical cases. The results suggest BriefCase effectively improves triage efficiency by providing timely notifications for suspected ICH.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Intracranial HemorrhageCT imagesArtificial IntelligenceTriage softwareNotification systemWorkflow optimizationDeep learningRadiologyHead CTImage analysis

Device Metadata

Submission Number
K180647
Company
Aidoc Medical, Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the BriefCase algorithm's performance (sensitivity and specificity) for ICH detection vary across different subtypes or severities of intracranial hemorrhage?; What is the real-world impact on patient outcomes or length of hospital stay when BriefCase is integrated into clinical workflow, beyond the measured time-to-notification?; How does the de-identification process ensure patient privacy while maintaining image integrity for accurate AI analysis, particularly when data is processed via a cloud server?; What are the computational requirements and processing time per study in a high-volume clinical setting, and how does this scale with increasing caseload?; Beyond ICH, are there plans to expand the BriefCase platform's AI capabilities to detect other acute neurological conditions visible on non-contrast head CTs?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score45/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, server, network, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
BriefCase - Aidoc Medical, Ltd. | ESL FDA AI Device Intelligence