Transpara
ScreenPoint Medical BV • Radiology • 11/21/2018
Device Purpose
Transpara™ is a software device utilizing machine learning algorithms to assist radiologists in the detection and diagnosis of breast cancer from screening mammograms by providing CAD marks, region-specific scores, and an overall exam score. Clinical and non-clinical studies demonstrate its ability to significantly improve radiologists' detection performance, particularly by increasing AUC, with high sensitivity for suspicious lesions and calcifications, without substantially increasing reading time.
Summary
Transpara™ is a software-only medical device designed as a concurrent reading aid for radiologists interpreting screening mammograms to identify and assess regions suspicious for breast cancer. The system utilizes machine learning algorithms, trained on extensive databases of biopsy-proven cancer, benign lesions, and normal tissue, to detect suspicious calcifications and soft tissue lesions. It processes DICOM mammography images, offering features like computer-aided detection (CAD) marks for highly suspicious findings, interactive querying of regions for a suspiciousness score, and an overall exam-based "Transpara™ Score" (1-10) indicating cancer likelihood. The software includes image pre-processing to ensure compatibility across images from different mammography vendors. Non-clinical standalone performance testing on a multi-vendor dataset demonstrated high sensitivity for calcifications (94.1%) and soft tissue lesions (72.0%) with low false positive rates. The Transpara™ Score effectively stratified exams, with 78% of cancer cases scoring in the highest likelihood category. A pivotal clinical reader study involving 14 radiologists and 240 cases showed that using Transpara™ significantly improved their cancer detection performance, increasing the average area under the ROC curve (AUC) from 0.866 to 0.886 (P=0.0019) without significantly impacting reading time. This improvement was observed for both soft tissue lesions and calcifications, and Transpara's standalone detection performance (AUC=0.887) was comparable to the average performance of unaided radiologists.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the "Transpara™ Score" calibration, aiming for approximately equal numbers of screening mammograms in each category, affect its discriminatory power for very rare or very common presentations of cancer in specific subpopulations?; What are the specific characteristics of the "large databases of biopsy proven examples" used for training the algorithms, particularly regarding diversity in patient demographics, breast density, and cancer subtypes?; The study showed an average AUC increase of 0.020; for the two radiologists where performance did not improve or slightly decreased, what were the potential contributing factors or case characteristics?; How does the software's pre-processing component standardize images from different vendors, and what is the performance variability, if any, when dealing with older versus newer imaging equipment or varying image acquisition protocols?; Given the standalone performance of Transpara™ approached that of radiologists, what are the ethical and practical considerations for its potential future role, beyond a concurrent reading aid, in the screening workflow?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly