Medscape Medical NewsAll articles

Study Watch

Verily Life Sciences LLC • Cardiovascular • 01/17/2019

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The Verily Study Watch is an over-the-counter, single-channel ECG device designed for adults to record, store, and transfer their cardiac rhythms for review by healthcare professionals. Utilizing a three-electrode system for enhanced signal quality and a cloud-based platform for data transmission and HCP access, it aims to facilitate remote cardiac monitoring without providing direct patient waveform review or automated analysis.

Summary

The Verily Study Watch is a wearable device designed for adult users (22 years or older), including those with known or suspected heart conditions, health-conscious individuals, and for use by healthcare professionals. Its primary function is to record, store, transfer, and display single-channel electrocardiogram (ECG) rhythms. The device is intended for over-the-counter use, allowing individuals to capture their ECG data, which is then made available to healthcare professionals for review. The Study Watch system comprises a miniaturized watch with two sensing electrodes and an additional right leg drive (RLD) electrode to enhance signal quality by reducing electrical interference. Users initiate a 30-second ECG recording via the watch's graphical user interface. While an animated waveform is briefly shown during capture, the patient does not have direct access to the stored waveform. The collected ECG data is transferred from the watch via a charging cradle and the "Study Hub" device to Verily's secure cloud server. Healthcare professionals can then view these time-stamped ECG waveforms through a dedicated web portal, which does not include automated analysis features. Clinical performance data demonstrated qualitative equivalence to a 12-lead ECG, with a Bland-Altman analysis showing minimal bias (-0.3 ms) and narrow limits of agreement (+/- 9.7 ms) for QRS intervals.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Study WatchECGSingle-channelWearable deviceRemote monitoringPhysiological dataHeart conditionsData transferCloud storageHealthcare professional portal

Device Metadata

Submission Number
K182456
Company
Verily Life Sciences LLC
Panel
Cardiovascular
Product Code
N/A
Data Type
Signals
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the inclusion of the Right Leg Drive (RLD) electrode in the Study Watch specifically improve ECG signal quality compared to similar single-lead devices without it, particularly in ambulatory settings with varying noise levels?; What are the specific data security and privacy measures implemented for the transfer and storage of ECG data from the Study Watch to Verily's cloud server and during access by healthcare professionals via the web portal?; Given that patients do not have direct access to their recorded ECG waveforms, what is the recommended protocol for patient feedback or engagement regarding their collected data, and how might this impact patient adherence or understanding?; What is the typical battery life of the Study Watch under conditions of frequent (e.g., multiple daily) ECG recordings, and what is the data storage capacity on the watch itself before requiring transfer via the Study Hub?; While the current web portal is for viewing only, are there future development plans to incorporate analytical tools or automated preliminary screening features for healthcare professionals, and how would these be validated?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score45/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud, server, remote, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Study Watch - Verily Life Sciences LLC | ESL FDA AI Device Intelligence