vascuCAP

Elucid Bioimaging Inc. • Radiology • 12/21/2018

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

vascuCAP is an advanced medical image analysis software that processes contrast-enhanced CT scans to provide detailed quantitative and qualitative assessments of arterial vessels, including lumen dimensions, stenosis, and plaque composition. By offering tools for 3D visualization, multi-planar reconstruction, and semi-automated measurements, it aims to assist clinicians in the stratification of patients with atherosclerosis, thereby complementing standard diagnostic pathways with objective data.

Summary

vascuCAP is a medical image analysis software designed to aid physicians in the stratification of patients with atherosclerosis by processing and analyzing multi-dimensional digital images acquired from contrast-enhanced CT scans. The system enables clinicians to visualize arterial vessels in 3D, along with rotatable curved multi-planar reconstruction (MPR) views and cross-sections. It offers tools for semi-automatic determination of contrasted lumen boundaries, stenosis measurements, and lumen diameters, while also allowing manual editing and Hounsfield unit analysis. vascuCAP facilitates the measurement of vessel length and provides color-coded maps for enhanced visualization, intended as a complementary tool to standard clinical care rather than a standalone diagnostic instrument. The performance of vascuCAP was evaluated through software verification and validation, including testing with phantom and clinical images to assess its accuracy in calculating anatomical structures and tissue characteristics, compared against anthropomorphic phantoms and expert pathologist annotations of histopathology specimens, respectively. This evaluation established specific analytic metrics for structural parameters like lumen area, wall area, stenosis, wall thickness, and plaque burden, as well as for tissue composition including calcified area, lipid-rich necrotic core (LRNC) area, and matrix area. Each metric is detailed with its tested range, bias, and statistical confidence, with an acknowledgment of potential overestimation for stenosis by diameter in very small lumens, a known limitation in CT angiography; the software also provides %stenosis by area to mitigate this. The vascuCAP A.1.2 version incorporates refined processing algorithms to improve upon the measurement performance of its predecessor.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

AtherosclerosisCT AngiographyImage Analysis SoftwareVessel LumenStenosis MeasurementPlaque CharacterizationMulti-planar ReconstructionHounsfield UnitPatient StratificationQuantitative Imaging

Device Metadata

Submission Number
K183012
Company
Elucid Bioimaging Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the vascuCAP software's performance in quantifying lipid-rich necrotic core (LRNC) area (R2: 0.5222) compare to other plaque components, and what are the clinical implications of this specific level of accuracy for predicting plaque vulnerability?; Given the noted potential for overestimation of stenosis by diameter in lumens smaller than the voxel size, what specific quantitative thresholds or alternative metrics (beyond %stenosis by area) does vascuCAP offer or recommend to mitigate misinterpretation in such cases?; The performance data for stenosis differs significantly between vessels ≥ 5.9mm and < 5.9mm; what are the underlying algorithmic or imaging physics reasons for this difference, and how does this impact its utility across different arterial beds?; How does the semi-automatic lumen boundary detection algorithm account for variations in contrast opacification, vessel tortuosity, and motion artifacts commonly encountered in clinical CT angiography, and what is the typical extent of manual editing required by clinicians?; What are the specific 'refined processing algorithms' in vascuCAP A.1.2 compared to A.1.1, and do these refinements demonstrably improve the accuracy or reduce the variability in measuring specific challenging plaque features like thin fibrous caps or intraplaque hemorrhage, if the software is capable of such measurements?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, bias, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange(vulnerab)
✓ Detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, VDR/VEX detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
vascuCAP - Elucid Bioimaging Inc. | ESL FDA AI Device Intelligence