Medscape Medical NewsAll articles

SIS Software version 3.3.0

Surgical Information Sciences, Inc. • Radiology • 03/19/2019

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

SIS Software version 3.3.0 is an advanced medical imaging application designed for enhanced visualization of the subthalamic nuclei (STN) and intraoperative functional planning, utilizing machine learning algorithms to process and fuse pre-operative MRI and post-operative CT images. The software leverages a database of high-resolution 7T MRI to improve STN identification on clinical MRIs and provides tools for co-registration and segmentation, aiming to improve accuracy in stereotactic neurosurgical procedures.

Summary

SIS Software version 3.3.0 is a medical imaging application intended for viewing, presentation, and documentation of medical images, incorporating modules for image processing, image fusion, and intraoperative functional planning, with a specific capability to aid in the visualization of the subthalamic nuclei (STN). The software employs machine learning and image processing techniques to enhance standard clinical MRI scans (1.5T or 3T) by referencing a database of high-resolution 7T MRI brain images; this approach leverages the superior clarity of 7T MRI to identify structures like the STN on a patient's clinical scans. Version 3.3.0 introduces the ability to co-register post-operative CT scans with the patient's pre-operative MRI (already processed for STN visualization) and to segment relevant features in the CT image, thereby facilitating comprehensive visualization for neurosurgical procedures intended for use by medical professionals such as surgeons, neurologists, and radiologists. Performance validation demonstrated high accuracy for STN visualization, with 98.3% of center of mass distances and 100% of surface distances below 2.0mm, and a Dice coefficient of 0.69, significantly outperforming standard care. The co-registration feature achieved high precision, with 95% confidence that 90% of MR to CT registrations will have reference point errors below 0.454mm. Electrode segmentation in post-operative CT scans also showed strong results, with 95% confidence that 90% of segmentations will have center of mass distances below 0.491mm and orientation differences below 2.486 degrees. The updated anomaly detection model improved sensitivity to 50% while maintaining high specificity (89.39%), enhancing overall system success to 98.33%. The STN smoothing functionality was also validated as performing acceptably without negatively impacting device output.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

SIS SoftwareMedical ImagingImage ProcessingImage FusionSubthalamic Nuclei (STN)Machine LearningMRICTCo-registrationStereotactic Surgery

Device Metadata

Submission Number
K183019
Company
Surgical Information Sciences, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the accuracy of STN visualization by SIS Software compare to manual segmentation by experienced neuroradiologists in a real-world clinical setting, beyond the validation dataset?; What is the learning curve for clinicians (surgeons, neurologists, radiologists) to effectively utilize all functionalities of SIS Software 3.3.0, particularly the co-registration and CT segmentation features?; Are there specific patient populations or MRI/CT scanner characteristics for which the performance of SIS Software (STN visualization, co-registration, segmentation) is known to be suboptimal?; How does the improved anomaly detection in version 3.3.0, specifically the increased sensitivity, translate to tangible benefits in clinical decision-making or workflow efficiency?; Could the machine learning model be further trained or adapted to visualize other deep brain structures relevant to neurosurgical procedures beyond the STN?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score45/100
SBOM Evidence✓ Detected in Summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials(software version)
✓ Detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SBOM, ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
SIS Software version 3.3.0 - Surgical Information Sciences, Inc. | ESL FDA AI Device Intelligence