Medscape Medical NewsAll articles

Aquilion ONE (TSX-305A/6) V8.9 with AiCE

Canon Medical Systems Corporation • Radiology • 06/12/2019

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Aquilion ONE (TSX-305A/6) V8.9 with AiCE is a computed tomography system designed for whole-body imaging, utilizing an advanced image reconstruction engine based on Deep Convolutional Neural Networks. This technology aims to significantly improve image quality by reducing noise and enhancing spatial and low-contrast resolution, while also enabling substantial radiation dose reduction compared to previous methods.

Summary

The Aquilion ONE (TSX-305A/6) V8.9 with AiCE is a whole-body, multi-slice helical Computed Tomography (CT) scanner designed to acquire and display cross-sectional volumetric data of the entire body, including organs like the brain and heart in a single rotation, for specialized diagnostic studies. Its core innovation is the Advanced intelligent Clear-IQ Engine (AiCE), a reconstruction technology that employs Deep Convolutional Neural Network (DCNN) methods. AiCE is engineered to differentiate signal from noise more effectively, thereby reducing image noise and enhancing overall image quality, particularly for abdomen, pelvis, lung, and cardiac applications. Performance evaluations utilizing phantoms demonstrated significant improvements with AiCE. These include an enhanced quantitative spatial resolution (7.4 lp/cm at 10% MTF versus 5.7 lp/cm with AIDR 3D), substantial dose reduction (79.6-82.4% compared to filtered back projection), a 12.2% improvement in low-contrast detectability, and a 29.2% noise reduction at equivalent dose levels compared to AIDR 3D. Additionally, AiCE achieved low-contrast detectability of 1.5 mm at 0.3% with 22.6mGy, and its noise texture was found to be more akin to standard filtered backprojection than iterative methods like FIRST, with diagnostic quality confirmed by radiologists for key applications.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Computed Tomography (CT)AiCE (Advanced intelligent Clear-IQ Engine)Deep Convolutional Neural Network (DCNN)Image ReconstructionNoise ReductionImage QualityDose ReductionWhole Body ImagingSpatial ResolutionLow-Contrast Detectability

Device Metadata

Submission Number
K183046
Company
Canon Medical Systems Corporation
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Generation
AI Subclass
image enhancement

Relevant Clinical Questions

  • Q1. How does the performance of AiCE's Deep Convolutional Neural Network compare to other DCNN-based image reconstruction algorithms in terms of computational efficiency and the potential for introducing new image artifacts?; What were the specific characteristics of the training dataset used for the AiCE Deep Convolutional Neural Network, and how might variations in this dataset impact its robustness across diverse patient populations or rare pathological findings?; Beyond the abdomen, pelvis, lung, and cardiac applications, what is the potential applicability and validated performance of AiCE for other anatomical regions or specialized CT examinations, such as neurological or musculoskeletal imaging?; What is the quantitative impact of AiCE on diagnostic accuracy or inter-reader variability in clinical practice when compared to predecessor technologies like AIDR 3D or FIRST, particularly in challenging low-contrast or high-noise scenarios?; Given that AiCE's noise texture is more similar to filtered backprojection, how does this affect radiologists' learning curve and subjective image assessment compared to the distinct textures often produced by iterative reconstruction algorithms like FIRST?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, neural network, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly