Acumen Hypotension Prediction Index EV1000 Clinical Platform, Acumen Hypotension Prediction Index HemoSphere Advanced Monitoring Platform, Acumen Hypotension Prediction Index HemoSphere Advanced Monitoring Platform - Pressure
Edwards Lifeciences, LLC • Cardiovascular • 05/21/2019
Device Purpose
The Acumen Hypotension Prediction Index is a software-based adjunctive tool designed for advanced hemodynamic monitoring, which aims to predict the likelihood of future hypotensive events in both surgical and non-surgical patients. By analyzing arterial pressure data to generate a predictive score alongside parameters like Dynamic Arterial Elastance and Systolic Slope, it offers clinicians additional physiological insight to potentially anticipate and manage hemodynamic instability.
Summary
The Acumen Hypotension Prediction Index (HPI) is a software feature designed to assist clinicians by providing insight into the likelihood of a patient experiencing a future hypotensive event, defined as a mean arterial pressure (MAP) below 65 mmHg for at least one minute. This adjunctive predictive cardiovascular indicator is intended for use in both surgical and non-surgical patients who are undergoing advanced hemodynamic monitoring. The system utilizes software running on compatible Edwards Lifesciences monitoring platforms (EV1000 Clinical Platform or HemoSphere Advanced Monitoring Platform) and is paired with an extravascular blood pressure transducer (FloTrac IQ or Acumen IQ) and a radial arterial catheter. It presents an HPI score from 0 (low likelihood) to 100 (high likelihood) of a hypotensive event occurring within the next 15 minutes. Beyond the primary HPI score, the feature also includes the Dynamic Arterial Elastance (Ea_dyn) and Systolic Slope (dP/dt) parameters, along with other graphical user interface enhancements, to provide a more comprehensive hemodynamic picture. It is crucial to note that the HPI is for informational reference only, and therapeutic decisions should not be based solely on this index; a full review of the patient's hemodynamics is always recommended. Clinical performance data demonstrated that the software's ability to predict hypotension in non-surgical patients is comparable to its previously established performance in surgical patients, supporting its expanded use in a broader patient population.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What specific physiological variables are used by the algorithm to calculate the Hypotension Prediction Index, and what is the relative weighting or importance of each?; How does the performance of the Acumen HPI (sensitivity, specificity, positive predictive value, negative predictive value) vary across different non-surgical patient populations (e.g., ICU medical patients vs. post-operative ICU patients)?; What is the typical lead time provided by the HPI before a hypotensive event in non-surgical patients, and how does this compare to surgical patients?; Are there known patient conditions, comorbidities, or concomitant medications that might affect the accuracy or reliability of the HPI, Ea_dyn, or dP/dt parameters?; What clinical studies have evaluated the impact of using the Acumen HPI feature on patient outcomes, such as a reduction in the incidence or duration of hypotensive episodes, or changes in therapeutic interventions?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly