LiverMultiScan (LMSv3)

Perspectum Diagnostics Ltd • Radiology • 06/27/2019

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

LiverMultiScan (LMSv3) is a software application that enhances non-invasive liver assessment by post-processing MR images to quantify key biomarkers like Proton Density Fat Fraction (PDFF), iron-corrected T1 (cT1), and T2*. It employs techniques such as automated liver segmentation and parametric mapping, including the LMS IDEAL and three-point Dixon methods for fat quantification, to provide clinicians with reproducible quantitative data intended to aid in liver disease diagnosis.

Summary

LiverMultiScan (LMSv3) is a standalone software application designed for non-invasive liver evaluation using magnetic resonance (MR) imaging data. Its primary purpose is to assist clinicians in diagnosis by generating, displaying, and reviewing 2D MR medical images and pixel maps of MR relaxation times. The software processes DICOM 3.0 compliant MR image datasets from compatible MR systems to visualize the liver's internal structure and derive quantitative physical parameters. Key functionalities include automated liver segmentation and region of interest (ROI) placements, enabling detailed assessment of selected liver regions for use as an aid to diagnosis. The methodology involves post-processing MR data to create parametric maps for Proton Density Fat Fraction (PDFF), T2*, T1, and iron-corrected T1 (cT1). LMSv3 offers flexibility in PDFF calculation, supporting both the LMS IDEAL method and the three-point Dixon methodology. This quantitative assessment provides measurements of liver triglyceride fat fraction, T2*, and cT1, which are compiled into a summary report, including histograms of segmented areas and PDFF intensities, for interpretation by specialists like radiologists and hepatologists. Performance testing on phantoms and in-vivo volunteer data demonstrated high repeatability and reproducibility for these measurements, with accuracy levels established for T1 (noting a consistent underestimation characteristic of MOLLI techniques), T2* and IDEAL PDFF (accurate over physiological ranges), and DIXON PDFF (relatively accurate, with minor deviations due to known fat bias).

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

LiverMultiScanMRILiver EvaluationPDFFcT1T2*Quantitative ImagingDICOMAutomated SegmentationParametric Mapping

Device Metadata

Submission Number
K190017
Company
Perspectum Diagnostics Ltd
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of the LMS IDEAL PDFF methodology compare to the three-point Dixon methodology in various liver disease states, particularly concerning accuracy and sensitivity to subtle changes in fat fraction?; What is the clinical impact of the automated liver segmentation feature on workflow efficiency and inter-operator variability compared to manual or ROI-based methods in routine practice?; Given the documented underestimation of T1 values by MOLLI-based techniques, what specific calibration or correction factors, if any, are applied or recommended when interpreting LMSv3-derived cT1 values in longitudinal patient monitoring?; How does the software handle motion artifacts or other common MR image quality issues, and what are the thresholds for image acceptability for reliable quantitative analysis?; What are the specific differences in accuracy and clinical utility between PDFF values derived using MAGNITUDE ONLY-IDEAL (for GE/Philips scanners) versus COMPLEX-IDEAL (for Siemens scanners) as implemented in LMSv3?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score20/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(dataset, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
LiverMultiScan (LMSv3) - Perspectum Diagnostics Ltd | ESL FDA AI Device Intelligence