Zio XT ECG Monitoring System, Zio AT ECG Monitoring System

iRhythm Technologies, Inc. • Cardiovascular • 08/23/2019

510(k)IEC 62304 Class C
FDA Summary PDF

Device Purpose

The Zio® ECG Utilization Service (ZEUS) System is a programmable diagnostic computer designed to analyze continuous single-lead ECG data from Zio Patches for long-term cardiac monitoring in adult patients. Its methodology combines automated beat-to-beat ECG analysis with review by a Certified Cardiographic Technician to generate comprehensive reports for clinicians, aiding in the diagnosis of symptomatic and asymptomatic cardiac events.

Summary

The Zio® ECG Utilization Service (ZEUS) System, developed by iRhythm Technologies, Inc., is a programmable diagnostic computer designed for the long-term monitoring, analysis, and reporting of cardiac events. It processes continuous, single-lead electrocardiogram (ECG) data acquired from patients using Zio XT or Zio AT Patches. The system is indicated for use in adults aged 18 years or older who may be asymptomatic or experiencing transient symptoms such as palpitations, shortness of breath, dizziness, or syncope, but is not intended for use in critical care settings. The ZEUS System's methodology involves downloading, storing, analyzing, and aggregating the complete ECG recording to provide beat-to-beat information. Automated ECG analysis is performed, with quantified sensitivity and positive predictivity levels meeting specified requirements. Following this automated processing, a Certified Cardiographic Technician (CCT) reviews the data and generates a final report. This comprehensive report is then provided to the prescribing clinician, who uses it in conjunction with their clinical judgment and experience to render a diagnosis.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

ECG analysisLong-term monitoringCardiac eventsAsymptomatic detectionZio PatchBeat-to-beat analysisProgrammable diagnostic computerSingle-lead ECGCertified Cardiographic TechnicianRemote patient monitoring

Device Metadata

Submission Number
K190593
Company
iRhythm Technologies, Inc.
Panel
Cardiovascular
Product Code
N/A
Data Type
Signals
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection/diagnosis

Relevant Clinical Questions

  • Q1. What are the specific sensitivity and positive predictivity values for the automated ECG analysis algorithms in the ZEUS System across various common arrhythmias?; How does the ZEUS System differentiate its analysis or reporting when data is sourced from a Zio XT Patch versus a Zio AT Patch, given their potentially different monitoring durations or capabilities?; What is the typical turnaround time from the completion of patient monitoring with a Zio Patch to the delivery of the final CCT-reviewed report to the clinician?; What cybersecurity measures, beyond adherence to guidance, are implemented within the ZEUS System to protect patient ECG data during download, storage, analysis, and transmission?; Are there any specific patient populations (e.g., those with certain comorbidities or on specific medications) for whom the ZEUS system's automated analysis might have known limitations or require more intensive CCT review?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score45/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(remote)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Zio XT ECG Monitoring System, Zio AT ECG Monitoring System - iRhythm Technologies, Inc. | ESL FDA AI Device Intelligence