Medscape Medical NewsAll articles

Cleerly Labs

Cleerly Inc • Radiology • 11/05/2019

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Cleerly Labs is a web-based software application that enables medical professionals to analyze CCTA images for the presence and extent of coronary artery disease by providing interactive tools for image visualization, segmentation, and quantification of coronary plaques and stenosis. The system utilizes CT data post-processing with manual and semi-automatic segmentation capabilities to measure vessel dimensions, plaque volumes (including calcified, non-calcified, and low-density non-calcified components), and stenosis, aiming to support clinical decision-making in CAD evaluation.

Summary

Cleerly Labs is a web-based software application designed for trained medical professionals to analyze cardiac computed tomography (CT) data. Its primary purpose is to aid in determining the presence and extent of coronary plaques and stenosis in patients who have undergone Coronary Computed Tomography Angiography (CCTA) for evaluation of actual or suspected coronary artery disease (CAD). The software functions as an interactive post-processing tool, capable of handling 2D and 3D coronary images from any CT scanner, and assists clinicians in navigating and manipulating these images to inform treatment paths for CAD patients. The software employs manual and semi-automatic segmentation tools, allowing users to edit lumen and vessel walls, demarcate stenosis and stents, and thus perform detailed coronary analysis. Its outputs include visual representations of coronary arteries, along with quantitative measurements such as distance and volume of the lumen wall, vessel wall, and various plaque types (calcified, non-calcified, low-density non-calcified). It also provides remodeling index, stenosis diameter, and area measurements, all based on user-refined segmentation. Performance data, when compared to expert readers, showed strong Pearson correlation coefficients for lumen volume (0.91), vessel volume (0.93), total plaque volume (0.85), and calcified plaque volume (0.94), with slightly lower correlation for non-calcified (0.74) and low-density non-calcified plaque (0.53), alongside high Bland-Altman agreement percentages for these measures.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Coronary Artery Disease (CAD)Computed Tomography Angiography (CCTA)Plaque QuantificationStenosis MeasurementImage SegmentationVessel AnalysisLow-Density Non-Calcified PlaqueDICOMPost-processing softwareInteractive visualization

Device Metadata

Submission Number
K190868
Company
Cleerly Inc
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. Given the lower Pearson correlation (0.53) for Low-Density Non-Calcified Plaque (LD-NCP) volume compared to other plaque types, what are the specific challenges in its automated or semi-automated quantification, and what steps are being taken to improve this accuracy?; How does the performance of Cleerly Labs' semi-automatic segmentation compare to fully manual segmentation by expert users in terms of time efficiency and inter-observer variability for complex lesions?; The software uses interpolated data for certain views; can you elaborate on the specific scenarios where interpolation is most heavily relied upon and the potential impact on diagnostic accuracy for subtle pathologies near the scanning resolution limit?; What is the defined training protocol for "trained medical professionals" to ensure proficient and consistent use of Cleerly Labs, especially concerning the manual editing and interpretation of semi-automated segmentation results?; Beyond the listed plaque characteristics (CP, NCP, LD-NCP), does Cleerly Labs offer any tools or potential for characterizing other high-risk plaque features, such as positive remodeling or spotty calcification, that are not explicitly quantified in Table 5?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, ML-BOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Cleerly Labs - Cleerly Inc | ESL FDA AI Device Intelligence