Medscape Medical NewsAll articles

aBSI

EXINI Diagnostics AB • Radiology • 08/05/2019

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The aBSI device is a cloud-based software system designed for quantitative analysis of skeletal disease from nuclear medicine bone scans, functioning as a Picture Archiving and Communications System (PACS) with specialized oncology tools. It utilizes an improved algorithm and an expanded skeletal atlas to calculate the Bone Scan Index (BSI), a measure shown in clinical studies to be associated with overall survival and disease progression in patients with metastatic castration-resistant prostate cancer.

Summary

The aBSI is a software-only medical device intended for use by trained healthcare professionals and researchers to facilitate the acceptance, transfer, storage, display, manipulation, quantification, and reporting of digital medical images acquired via nuclear medicine (NM) imaging. Its core function is to provide a fully quantitative assessment of a patient’s skeletal disease, presented as the Bone Scan Index (BSI), which represents the fraction of the total skeleton weight affected by disease. The device integrates general Picture Archiving and Communications System (PACS) tools with specific clinical applications for oncology, such as lesion marking and quantitative analysis. The methodology involves an improved algorithm for detecting high-intensity regions (hotspots) within a refined skeletal atlas that now covers the entire femur and humerus. Images are normalized to a predefined level for healthy bone tissue, and the system is delivered as a cloud-based service, an update from its predicate's CD or downloadable file installation. Clinical performance data for aBSI was established through two studies involving patients with metastatic castration-resistant prostate cancer (mCRPC). Study I, a Phase 3 validation with 721 evaluable patients, found that aBSI was significantly associated with overall survival (OS), symptomatic progression, and time to opiate use, with aBSI remaining an independent predictor of OS in multivariate models. Study II, a retrospective analysis of 169 mCRPC patients, demonstrated that an increase in aBSI had a similar association with OS as the PCWG criteria for radiographic progression, and quantified the aBSI increase in patients meeting PCWG criteria. Bench testing further confirmed the linearity, accuracy, precision, and reproducibility of the BSI calculation with different cameras and multiple images. The device differs from its predicate by removing CT image display capability and being cloud-based, among other technological enhancements aimed at improving efficiency and analytical scope.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

aBSIBone Scan IndexNuclear MedicineOncologyQuantitative AssessmentSkeletal DiseaseImage AnalysisProstate CancerOverall SurvivalPACS

Device Metadata

Submission Number
K191262
Company
EXINI Diagnostics AB
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the refined skeletal atlas in aBSI, now covering the entire femur and humerus, impact the sensitivity and specificity of hotspot detection and BSI calculation compared to the previous version that covered only down to ¾ of these bones?; What were the specific algorithmic improvements made to the hotspot detection in aBSI, and how do these changes quantitatively affect performance metrics such as detection accuracy, false positive/negative rates, or processing time compared to the predicate EXINI device?; Given that aBSI showed an association with overall survival comparable to PCWG criteria in Study II, what is the incremental clinical utility or advantage of using aBSI over or in conjunction with established PCWG criteria in routine oncological practice for mCRPC patients?; Study I demonstrated aBSI's prognostic value in a large mCRPC cohort. Has the performance of aBSI been evaluated in other cancer types with bone metastases or in different stages of prostate cancer (e.g., non-castration resistant)?; Considering aBSI is now a cloud-based service, what specific measures are in place to ensure data security, patient privacy (e.g., HIPAA compliance), data integrity during transfer and storage, and system reliability/uptime for clinical use?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score35/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cloud)
✓ Detected
HBOMHardware Bill of Materials(camera)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, HBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
aBSI - EXINI Diagnostics AB | ESL FDA AI Device Intelligence