Medscape Medical NewsAll articles

ProFound AI Software V2.1

iCAD Inc. • Radiology • 10/04/2019

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

ProFound™ AI Software V2.1 is a computer-assisted detection tool that employs deep learning algorithms to identify suspicious soft tissue densities and calcifications in digital breast tomosynthesis images, providing radiologists with visual cues and quantitative scores indicating the algorithm's confidence of malignancy. Its methodology involves processing 3D DBT slices for pattern recognition of lesions, with its scientific validation demonstrated through non-clinical performance studies confirming efficacy and non-inferiority across various DBT systems, including newly supported Siemens platforms.

Summary

ProFound™ AI Software V2.1 is a radiological computer-assisted detection and diagnosis (CAD) tool designed to aid physicians in interpreting digital breast tomosynthesis (DBT) exams. The software utilizes deep learning algorithms for pattern recognition to identify and mark suspicious soft tissue densities (such as masses, architectural distortions, and asymmetries) and calcifications within 3D DBT slices. It provides visual overlays on the images and assigns two types of scores: a 'Certainty of Finding' score for each detected lesion and a 'Case Score' for the overall exam, both ranging from 0 to 100, reflecting the algorithm's confidence in the malignancy of a detection or case, respectively, to guide radiologists in their assessment. A key update in version 2.1 is the expansion of compatibility to include Siemens Mammomat Inspiration and Revelation DBT systems, alongside previously supported Hologic and GE systems, while maintaining the core lesion detection technology and scoring system of its predecessor. Non-clinical performance for these new Siemens compatibilities was evaluated through standalone studies using Siemens Standard and Empire Reconstruction DBT image datasets, which demonstrated that case-level sensitivity, lesion-level sensitivity, false positive rates, and specificity met predefined design specifications. Furthermore, comparative non-inferiority testing against its performance with Hologic DBT systems showed that ProFound AI V2.1 maintains comparable efficacy (in terms of sensitivity, Area Under Curve (AUC), and False Positives Per Image volume (FPPI)) when used with the newly supported Siemens systems. It is important to note that the Certainty of Finding and Case Scores are relative, based on a model population with 50% cancer prevalence, and are intended as a relative level of concern rather than absolute probabilities of malignancy for individual patients in typical screening populations.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Digital Breast Tomosynthesis (DBT)Artificial Intelligence (AI)Deep LearningComputer-Assisted Detection (CAD)Malignancy DetectionSoft Tissue DensitiesCalcificationsCertainty of Finding ScoreCase ScoreNon-inferiority Testing

Device Metadata

Submission Number
K191994
Company
iCAD Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection/diagnosis

Relevant Clinical Questions

  • Q1. How does the 'Certainty of Finding' score calibration, based on a 50% cancer prevalence model, impact its practical utility and interpretation in real-world screening populations where prevalence is significantly lower?; What specific deep learning architectures are employed in the ProFound AI V2.1 algorithm, and how were they optimized for detecting diverse lesion types such as masses, architectural distortions, asymmetries, and calcifications?; Beyond sensitivity, specificity, AUC, and FPPI, were other performance metrics like radiologist reading time reduction or impact on biopsy rates assessed in the non-clinical studies for the newly supported Siemens DBT systems?; The documentation mentions a 'stratified bootstrap procedure' for performance estimation; could you elaborate on the stratification variables used and how this procedure addresses potential biases in the test datasets for Siemens systems?; How does the ProFound AI V2.1 software account for variations in image acquisition protocols, image quality, or reconstruction parameters across the different compatible Digital Breast Tomosynthesis systems (Hologic, GE, Siemens) to ensure consistent detection performance?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score25/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset, bias)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
ProFound AI Software V2.1 - iCAD Inc. | ESL FDA AI Device Intelligence