PhantomMSK Trauma

OrthoGrid Systems Inc. • Radiology • 12/07/2019

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

PhantomMSK Trauma is an image-processing software intended to enhance the accuracy of orthopedic trauma component placement by providing intraoperative fluoroscopic image analysis tools, including templating, measurement, and distortion correction. The system utilizes a radiopaque calibration array with C-arm imaging to calculate and correct fluoroscopic distortions, thereby aiding surgeons in assessing implant and anatomical alignment during procedures.

Summary

PhantomMSK Trauma is an image-processing software system designed to aid surgeons in the precise positioning of orthopedic trauma components during operations. It functions by analyzing fluoroscopic images acquired from a C-arm, offering tools for templating, measurement, and correcting image distortion. The system is software-based and operates on standard 'commercial off-the-shelf' computer hardware, interfacing with fluoroscopic images displayed outside the sterile field for the surgeon's discretionary use. It is not intended for primary image interpretation and requires clinical judgment for proper use. The scientific basis of the device includes a method to address fluoroscopic distortion, which can be caused by external electromagnetic interference and the inherent characteristics of mapping a planar image onto a curved input phosphor. PhantomMSK Trauma employs software algorithms in conjunction with a proprietary radiopaque calibration array, which attaches to the C-arm's image intensifier, to calculate and correct these distortions. Verification and validation testing, performed at both code and system levels using specific C-arm models (GE OEC 9900 and 9800) and defined image intensifier sizes, confirmed that its templating, measurement, and distortion correction tools performed as intended and met established acceptability criteria.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Orthopedic TraumaImage ProcessingFluoroscopyIntraoperative PositioningDistortion CorrectionTemplatingMeasurement ToolsC-armRadiopaque CalibrationSurgical Assistance

Device Metadata

Submission Number
K192279
Company
OrthoGrid Systems Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. What is the quantifiable improvement in surgical precision (e.g., alignment accuracy, screw placement) when using PhantomMSK Trauma's distortion correction compared to standard fluoroscopy?; How does the system's performance, particularly distortion correction accuracy, vary across different C-arm models and ages, beyond the specific GE OEC models tested?; What is the typical learning curve for a surgeon to become proficient in utilizing all the features of PhantomMSK Trauma, especially for complex trauma cases?; Are there any studies comparing the operative time or patient outcomes for procedures performed with PhantomMSK Trauma versus those without?; How does the radiopaque calibration array affect the overall workflow and imaging time during a typical orthopedic trauma procedure?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials(hardware)
✓ Detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, HBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
PhantomMSK Trauma - OrthoGrid Systems Inc. | ESL FDA AI Device Intelligence