Medscape Medical NewsAll articles

Transpara

Screenpoint Medical B.V. • Radiology • 12/10/2019

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

Transpara™ is a radiological computer-assisted detection and diagnosis software designed to aid physicians in interpreting screening mammograms by identifying suspicious breast lesions and assessing their likelihood of malignancy. Utilizing machine learning algorithms trained on extensive databases and DICOM integration, the software analyzes mammograms to provide CAD marks, region-specific scores, and an overall exam score, with version 1.5.0 demonstrating improved detection performance and expanded vendor compatibility.

Summary

Transpara™ is a software-only medical device designed to assist physicians in the interpretation of screening mammograms for breast cancer detection and diagnosis. Its primary purpose is to serve as a concurrent reading aid, identifying regions suspicious for breast cancer, such as soft tissue lesions and calcifications, and assessing their likelihood of malignancy. The system provides output in several forms: computer-aided detection (CAD) marks on suspicious areas, region-based scores displayed upon user query, and an overall exam score (Transpara™ Score from 1-10) indicating the exam's likelihood of containing cancer. The intended users are qualified physicians reading screening mammograms, and the patient population is women undergoing such screenings; however, patient management decisions should not be based solely on Transpara™'s analysis. The Transpara™ system operates as a DICOM node, receiving images from mammography devices or PACS archives, and employs a processing server and an optional viewer. Its core technology involves machine learning algorithms trained on large, biopsy-proven datasets of cancerous, benign, and normal breast tissue to recognize suspicious findings. The software pre-processes images to ensure compatibility across different mammography vendor equipment, allowing consistent analysis. Key user interface functions include activating CAD marks (with a focus on low false positives for soft tissue lesions), querying specific regions for a suspiciousness level, and viewing the exam-based Transpara™ Score. Non-clinical performance testing of Transpara™ version 1.5.0 demonstrated improved detection performance compared to its predicate (version 1.3.0) for multiple mammography manufacturers and confirmed similar performance for newly supported Fujifilm modalities, indicating its effectiveness in detecting lesions.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Transpara™MammographyBreast Cancer DetectionComputer-Aided DetectionRadiological SoftwareMachine LearningImage AnalysisDICOMCalcificationsSoft Tissue Lesions

Device Metadata

Submission Number
K192287
Company
Screenpoint Medical B.V.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection/diagnosis

Relevant Clinical Questions

  • Q1. How does the 'exam based Transpara™ Score' (1-10) quantitatively correlate with established risk stratification models or BI-RADS categories, and what was the specific methodology used for validating this scoring system's clinical utility?; What were the precise sensitivity, specificity, and area under the ROC curve (AUC) metrics from the validation testing that demonstrate Transpara™ 1.5.0's 'better detection performance' compared to version 1.3.0, and what were the absolute and relative improvements observed for different lesion types (calcifications vs. soft tissue masses)?; Can you provide more technical details on the image pre-processing techniques that enable Transpara™ to analyze images from different vendors using the same core algorithms, and how is the robustness of these techniques validated against variations in image acquisition protocols?; The system aims for a 'very low false positive rate' for soft tissue lesion marks. What is the quantified false positive rate per image or per exam for these marks, how does it compare to the false positive rate for calcification marks, and what is the trade-off with sensitivity for these soft tissue lesions?; Given that the pivotal reader study was conducted with the predicate device (Transpara 1.3.0), what specific bridging data or analysis was provided to extrapolate the safety and effectiveness findings to Transpara™ 1.5.0, particularly concerning the algorithmic improvements and expanded modality support?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Transpara - Screenpoint Medical B.V. | ESL FDA AI Device Intelligence