Medscape Medical NewsAll articles

Accelerate Pheno System, Accelerate PhenoTest BC Kit

Accelerate Diagnostics, Inc. • Microbiology • 09/15/2020

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The Accelerate PhenoTest™ BC kit and Accelerate Pheno™ system provide rapid microbial identification from positive blood cultures using fluorescence in situ hybridization (FISH) and determine antimicrobial susceptibility through morphokinetic cellular analysis (MCA). This automated platform aims to accelerate diagnostic turnaround times for bacteremia and fungemia by analyzing organism-specific ribosomal RNA for identification and observing real-time cellular responses to antibiotics for susceptibility profiling.

Summary

The Accelerate PhenoTest™ BC kit, used with the Accelerate Pheno™ system, is an in vitro diagnostic tool designed for rapid identification and antimicrobial susceptibility testing (AST) of microorganisms directly from positive blood cultures. It aims to aid in the diagnosis of bacteremia and fungemia by identifying a broad panel of Gram-positive and Gram-negative bacteria, as well as Candida albicans and Candida glabrata, typically within two hours using qualitative nucleic acid fluorescence in situ hybridization (FISH). The system then performs AST for detected bacterial organisms against a comprehensive list of relevant antimicrobial agents, with results available in approximately seven hours total, employing quantitative morphokinetic cellular analysis (MCA) to determine antimicrobial susceptibility. The system's methodology involves automated sample preparation via gel electrofiltration, followed by cell capture and FISH targeting ribosomal RNA for identification, enhanced by an optical filter and noise rejection algorithms. For AST, MCA technology leverages digital microscopy and machine learning to monitor the real-time morphokinetic responses of individual microbial cells and microcolonies to various antimicrobials, enabling the derivation of Minimum Inhibitory Concentration (MIC) values. Recent updates include revised algorithms for specific Pseudomonas aeruginosa assays (aztreonam, cefepime, ceftazidime, meropenem, piperacillin-tazobactam), automated quality control, and an improved computing architecture. Performance evaluations for these modified P. aeruginosa assays generally showed high essential and categorical agreement with reference methods, although specific antimicrobials exhibited variations in error rates that were further analyzed.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Antimicrobial Susceptibility Testing (AST)Fluorescence In Situ Hybridization (FISH)Morphokinetic Cellular Analysis (MCA)Positive Blood CultureMicrobial IdentificationBacteremiaFungemiaPseudomonas aeruginosaMinimum Inhibitory Concentration (MIC)Rapid Diagnostics

Device Metadata

Submission Number
K192665
Company
Accelerate Diagnostics, Inc.
Panel
Microbiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the Morphokinetic Cellular Analysis (MCA) differentiate between bacteriostatic and bactericidal effects of antimicrobials at the single-cell level, and are these differentiations reflected in the MIC reporting?; What is the observed impact of the additional 720-760 nm optical filter and noise rejection algorithms on the identification accuracy and rate of indeterminate results, particularly in samples with high debris levels?; Given the reported variations in error rates for certain Pseudomonas aeruginosa-antibiotic combinations (e.g., meropenem minor errors, initial cefepime/ceftazidime very major errors), what specific morphokinetic features or algorithmic adjustments contribute to these discrepancies, and what is the clinical implication of MICs tending to be higher for cefepime and meropenem with P. aeruginosa?; For polymicrobial infections, what is the system's sensitivity and specificity for detecting and identifying each individual organism, and how does it prioritize which organism(s) proceed to AST if multiple treatable bacteria are identified?; Considering the automated QC process uses complementary sequences coupled to polymer microspheres, how does this method's stability and performance compare to traditional biological QC strains over extended periods and across different reagent lot variations?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(cellular, platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Accelerate Pheno System, Accelerate PhenoTest BC Kit - Accelerate Diagnostics, Inc. | ESL FDA AI Device Intelligence