Aquilion ONE (TSX-306A/3) V10.0 with Spectral Imaging System
Canon Medical Systems Corporation • Radiology • 02/13/2020
Device Purpose
The Aquilion ONE (TSX-306A/3) V10.0 with Spectral Imaging System is an advanced computed tomography scanner designed for comprehensive whole-body and single-rotation whole-organ imaging, with a focus on enhancing diagnostic information while managing radiation dose. Its methodology combines rapid KV switching for spectral imaging to differentiate material compositions, FIRST iterative reconstruction for dose reduction and improved spatial resolution, and an AiCE Deep Convolutional Neural Network for substantial noise reduction and image quality enhancement, supported by performance testing demonstrating these capabilities.
Summary
The Aquilion ONE (TSX-306A/3) V10.0 with Spectral Imaging System is a whole-body multi-slice helical CT scanner, comprising a gantry, couch, and console for data processing and display. Its primary purpose is to acquire and display cross-sectional volumes of the entire body, including the head, with the capability to image whole organs such as the brain, heart, and pancreas in a single rotation. These comprehensive volume datasets enable trained physicians to perform specialized studies of entire organs, facilitating detailed anatomical assessment for determining courses of treatment. The system integrates several advanced imaging technologies to enhance diagnostic capabilities. The Spectral Imaging System utilizes rapid KV switching to acquire two nearly simultaneous CT images at distinct energy levels, allowing for differentiation of material composition in organs, tissues, and contrast agents; the total X-ray dose is the sum of the doses from each energy level. It incorporates FIRST, an iterative reconstruction algorithm designed to reduce radiation exposure dose while improving high-contrast spatial resolution for applications including the abdomen, pelvis, chest, cardiac, extremities, and head. Additionally, AiCE, a noise reduction algorithm employing Deep Convolutional Neural Network methods, enhances image quality and reduces noise in scans of the abdomen, pelvis, lung, cardiac, brain, inner ear, and extremities. Performance testing confirmed the diagnostic quality of images, with AiCE demonstrating significant dose reduction (e.g., 69-81% compared to filtered back projection), improved low-contrast detectability, and noise reduction, while Spectral Imaging showed reduced beam hardening artifacts and a high linear correlation between CT number and iodine concentration.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What is the quantitative impact of the FIRST algorithm on exposure dose and high-contrast spatial resolution across different anatomical regions, and how does this compare to other iterative reconstruction techniques?; How does the AiCE algorithm's Deep Convolutional Neural Network specifically differentiate between noise and fine anatomical detail, particularly in low-dose pediatric scans or in regions with inherently low contrast?; What are the specific advantages and limitations of rapid KV switching in the Spectral Imaging System for quantitative material decomposition (e.g., accuracy of iodine maps, virtual non-contrast images) compared to dual-source or detector-based spectral CT approaches?; The document mentions a "high linear correlation between CT number and iodine concentration." What is the validated range and precision of this correlation, and how does it perform across different patient body habitus or contrast administration protocols?; Given the distinct benefits of AiCE (noise/dose reduction) and Spectral Imaging (material differentiation), what are the optimal acquisition and reconstruction protocols when both features are employed simultaneously, and are there any synergistic effects or trade-offs observed in image quality or diagnostic information?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly