Medscape Medical NewsAll articles

MammoScreen

Therapixel • Radiology • 03/25/2020

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

MammoScreen is a radiological computer-assisted detection software that employs deep learning algorithms trained on biopsy-proven examples to aid physicians in identifying suspicious calcifications and soft tissue lesions in screening FFDM. The system processes mammograms to highlight findings and assign a 1-10 suspicion score, with clinical studies demonstrating improved radiologist detection performance when using the software.

Summary

MammoScreen is a software-only medical device designed as a concurrent reading aid for physicians interpreting screening Full-Field Digital Mammograms (FFDM). Its primary purpose is to assist in identifying focal findings suspicious for breast cancer, such as calcifications and soft tissue lesions, and to assess their level of suspicion. The system comprises a processing server and a web interface, utilizing advanced image analysis algorithms, including deep learning machine learning components. These algorithms are trained on extensive databases of biopsy-proven breast cancer examples, benign lesions, and normal tissue. MammoScreen processes FFDM images and provides output as CAD marks highlighting suspicious findings, along with a "MammoScreen Score" on a 1-10 scale indicating increasing suspicion, with findings scoring 5 or higher initially prioritized for review. Standalone performance testing demonstrated MammoScreen's capability in the absence of a clinician, achieving a combined ROC AUC of 0.883 at the mammogram level and 0.911 at the breast level across images from Hologic and GE devices. The system showed notable performance for detecting both soft tissue lesions (LROC AUC 0.877) and calcifications (LROC AUC 0.942) at the finding level. A retrospective multi-reader multi-case clinical study involving 14 radiologists and 240 mammograms found that using MammoScreen as an aid improved radiologists' cancer detection performance, increasing the average Area Under the ROC Curve (AUC) from 0.77 (unaided) to 0.80 (aided). This improvement was observed for 11 out of 14 radiologists and was statistically significant, though average reading time per case slightly increased with MammoScreen assistance. The system's standalone performance (AUC 0.79) was found to be non-inferior to the average performance of unaided radiologists.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

MammoScreenFFDMComputer-Assisted DetectionMachine LearningDeep LearningBreast Cancer ScreeningSuspicion ScoreROC AUCSensitivitySpecificity

Device Metadata

Submission Number
K192854
Company
Therapixel
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection/diagnosis

Relevant Clinical Questions

  • Q1. How does the MammoScreen algorithm's performance (sensitivity/specificity) vary across different breast density categories, and was this factored into the training dataset?; The clinical study showed an average increase in reading time; what is the distribution of this increase among radiologists, and are there specific workflow integrations that could mitigate this?; What were the characteristics of the false positives generated by MammoScreen in the standalone testing, and how do they compare to typical false positives identified by radiologists alone?; Given the performance differences observed between Hologic and GE devices in standalone testing (e.g., LROC AUC for soft tissue lesions was 0.837 for Hologic vs. 0.900 for GE), what steps are taken to ensure consistent performance across a wider range of mammography systems?; The MammoScreen Score is a 1-10 scale. How was the calibration of this score to the actual probability of malignancy established and validated, particularly for the thresholds (e.g., MS5) used for default display?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score10/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(training data, machine learning, deep learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
MammoScreen - Therapixel | ESL FDA AI Device Intelligence