Medscape Medical NewsAll articles

InferRead Lung CT.AI

Beijing Infervision Technology Co.,Ltd. • Radiology • 07/02/2020

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

InferRead Lung CT.AI is a software tool that employs advanced image analysis algorithms to aid radiologists in detecting pulmonary nodules on chest CT scans from asymptomatic patients. Its server-based methodology processes images to provide toggleable annotations and quantitative nodule data, with clinical studies demonstrating significant enhancements in detection accuracy and reduced reading times for users.

Summary

InferRead Lung CT.AI is a software-as-a-service (SaaS) solution designed to aid radiologists in the detection of pulmonary nodules during the review of CT examinations of the chest on an asymptomatic population. The system utilizes a browser/server architecture; its server processes chest CT images received from PACS, RIS, or CT scanners using integrated algorithm logic and a database, and then provides output annotations regarding lung nodules for viewing on existing PACS workstations. Key software modules include Image reception (Docking Toolbox), Image predictive processing (DLServer), Image storage (RePACS), and Image display (NeoViewer), with the system providing nodule characteristics such as diameter and volume without modifying the original CT scan, instead overlaying toggleable CADe marks. The device's science involves algorithmic identification of solid and sub-solid nodules 4mm and larger, also supporting visualization of smaller ones. Non-clinical evaluations confirmed software integrity, measurement reproducibility, accuracy, and nodule detection sensitivity comparable to established systems. A pivotal multi-reader, multi-case clinical study involving 10 radiologists and 249 scans demonstrated that the use of InferRead Lung CT.AI significantly improved radiologists' nodule detection performance, evidenced by a 0.073 increase in the area under the LROC curve, and also significantly decreased reading times by an average of 23 seconds per scan compared to unaided readings.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Pulmonary nodulesCT scanRadiologyArtificial Intelligence (AI)Computer-Assisted Detection (CADe)Lung cancer screeningImage analysisAsymptomatic populationDetection performanceSaaS (Software as a Service)

Device Metadata

Submission Number
K192880
Company
Beijing Infervision Technology Co.,Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
detection

Relevant Clinical Questions

  • Q1. What specific deep learning architectures or algorithms are employed by the DLServer module for nodule detection, and how were they trained and validated prior to the pivotal study?; How does the system's performance vary with different types and sizes of pulmonary nodules (e.g., solid vs. sub-solid, ground-glass opacities, nodules <4mm vs. >4mm)?; What was the range of experience levels of the 10 board-certified radiologists in the pivotal study, and did the device's impact on detection accuracy and reading time differ across these experience levels?; The device provides nodule characteristics such as maximum axial plane longest diameter, mean diameter, and volume; how accurate are these quantitative measurements compared to manual measurements or pathological findings?; Given the SaaS model, what are the data security, privacy (HIPAA compliance), and interoperability protocols implemented, especially when dedicated servers are located at hospitals and connected to hospital networks?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, annotation)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
InferRead Lung CT.AI - Beijing Infervision Technology Co.,Ltd. | ESL FDA AI Device Intelligence