Medscape Medical NewsAll articles

7D Surgical System Cranial Biopsy and Ventricular Catheter Placement Application

7D Surgical Inc. • Neurology • 11/27/2019

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

The 7D Surgical System Cranial Biopsy and Ventricular Catheter Placement Application is designed as a neurosurgical aid, providing stereotaxic image guidance for enhanced accuracy in cranial procedures such as biopsies and ventricular catheter placement. It achieves this through a combination of structured light imaging for intraoperative surface registration and optical tracking of surgical instruments relative to patient anatomy.

Summary

The 7D Surgical System Cranial Biopsy and Ventricular Catheter Placement Application is a stereotaxic image guidance system designed for precise spatial positioning and orientation of neurosurgical instruments during cranial procedures. It also serves as the primary surgical luminaire. The system utilizes machine vision and structured light imaging to capture intraoperative 3D anatomical data, which is registered with preoperative DICOM images. This enables real-time navigation of optically tracked instruments, including a specialized Biopsy Guide compatible with the IZI Navigable Brain Biopsy Cannula, employing passive-marker technology and an articulating arm for accurate instrument placement for procedures like biopsies and ventricular catheter insertions. Non-clinical testing, including surgical simulations on phantom models, was conducted to verify the system's performance and safety. The system demonstrated a mean Target Registration Error (TRE) of 1.36 mm and a mean Trajectory Angle Error (ATE) of 1.35 degrees, indicating high accuracy. Extensive verification and validation activities confirmed that the device meets its design specifications, usability requirements, and risk control measures. The system also adheres to standards for biocompatibility, sterilization, and electrical safety (IEC 60601 series, IEC 60825-1). Clinical trials were not deemed necessary due to the established nature of its underlying technology and equivalence to predicate devices for the stated indications for use.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Stereotaxic Image GuidanceNeurosurgeryCranial BiopsyVentricular Catheter PlacementStructured Light ImagingOptical TrackingSurgical NavigationTarget Registration Error (TRE)Angular Trajectory Error (ATE)Phantom Model Testing

Device Metadata

Submission Number
K192945
Company
7D Surgical Inc.
Panel
Neurology
Product Code
N/A
Data Type
Images
Clinical Function
Intervention
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the performance of the structured light imaging and registration process vary with different cranial surface characteristics or in the presence of surgical field contaminants like blood or irrigation?; What is the documented learning curve for surgeons to achieve optimal proficiency with the 7D Surgical System for cranial biopsies and ventricular catheter placements compared to other navigation systems?; Are there specific types of cranial pathologies or anatomical variations where the system's Target Registration Error (TRE) and Angular Trajectory Error (ATE) might deviate significantly from the reported phantom model results?; How does the system's integrated surgical luminaire function interact with or potentially affect the optical tracking accuracy, especially under varying ambient light conditions in the operating room?; What are the detailed failure modes and recovery mechanisms for the passive-marker tracking system, particularly concerning marker occlusion or misidentification during a procedure?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score0/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials
- Not detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, ML-BOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
7D Surgical System Cranial Biopsy and Ventricular Catheter Placement Application - 7D Surgical Inc. | ESL FDA AI Device Intelligence