Medscape Medical NewsAll articles

Rapid ICH

iSchemaView Incorporated • Radiology • 03/31/2020

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

RAPID ICH is an AI-powered software designed to expedite the triage of suspected intracranial hemorrhage by analyzing non-contrast head CT scans and notifying clinicians of potential positive cases in parallel with standard care. Its methodology relies on a deep learning algorithm to achieve high sensitivity and specificity in ICH detection, aiming to improve workflow efficiency in acute care settings without replacing standard diagnostic procedures.

Summary

RAPID ICH, developed by iSchemaView, Inc., is a radiological computer-assisted triage and notification software designed to aid in the workflow prioritization of suspected intracranial hemorrhage (ICH). It operates as a module within the integrated RAPID Platform, analyzing non-enhanced head CT (NCCT) images using an artificial intelligence algorithm. The system processes DICOM-compliant image data, and upon identifying a suspected ICH, it notifies the clinical team via PACS/Workstation, email, and a mobile application. These notifications include compressed preview images intended for informational purposes only, prompting clinicians to review the full, original images on a diagnostic workstation as part of the standard care pathway; the software does not alter the original medical image and is not intended as a diagnostic device. The core science behind RAPID ICH involves a deep learning algorithm trained on medical images to detect potential ICH findings. The system functions in parallel with existing standard of care workflows, aiming to expedite the review of critical cases without removing any cases from the standard worklist. Performance data from a retrospective, blinded, multicenter study involving 336 cases demonstrated a sensitivity of 89.9% and a specificity of 94.3% in identifying ICH, both exceeding an 80% performance goal. The average time to notification, encompassing DICOM exam acquisition, de-identification, analysis, and alert dissemination, was reported as 2.28 minutes. The software is intended to be used in conjunction with other patient information and professional judgment.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

Intracranial Hemorrhage (ICH)Artificial IntelligenceTriage SoftwareNCCT (Non-Contrast CT)Notification SystemDeep LearningRadiological ImagingWorkflow PrioritizationSensitivitySpecificity

Device Metadata

Submission Number
K193087
Company
iSchemaView Incorporated
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the AI algorithm differentiate between true ICH and potential mimics, such as calcifications or other hyperdense lesions, especially given the caution about IV contrast leading to false positives?; What was the range of ICH volumes and locations included in the training and validation datasets, and how does the software's sensitivity vary with the size, subtlety, and location of the hemorrhage?; Beyond sensitivity and specificity, what are the reported positive predictive value (PPV) and negative predictive value (NPV) of RAPID ICH in diverse real-world clinical populations with varying ICH prevalence?; How does the system handle images with significant motion artifacts, beam hardening, or other common CT quality issues, and what is the documented failure rate or rate of non-interpretable analyses due to poor image quality?; What specific features of the deep learning architecture contribute to its performance, and how was the algorithm validated against diverse patient demographics, co-morbidities, and scanner types/manufacturers beyond the 336 cases mentioned?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score45/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(platform)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
Rapid ICH - iSchemaView Incorporated | ESL FDA AI Device Intelligence