Medscape Medical NewsAll articles

uAI EasyTriage-Rib

Shanghai United Imaging Intelligence Co., Ltd. • Radiology • 01/15/2021

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

uAI EasyTriage-Rib is an AI-powered software tool designed to analyze CT chest images for the detection of multiple acute rib fractures, aiming to improve radiology workflow by prioritizing time-sensitive trauma cases for radiologist review. The system uses a deep learning algorithm to identify suspected fractures and provides notifications to clinicians, functioning alongside standard procedures to facilitate prompt image interpretation without making diagnostic decisions.

Summary

uAI EasyTriage-Rib is a radiological computer-assisted software designed for analyzing CT chest images to assist hospital networks and trained radiologists in workflow triage. Its primary function is to flag and prioritize trauma studies with suspected findings of three or more acute rib fractures. The system utilizes an artificial intelligence algorithm and consists of two modules: the uAI EasyTriage-Rib Server and the uAI EasyTriage-Rib Studylist Application, which provides the user interface for notifications. It operates as a standalone application in parallel with ongoing standard of care, presenting users with notifications that include compressed preview images for informational purposes only; these previews are not intended for diagnostic use beyond notification, and the device does not alter original medical images nor is it intended for diagnostic use. The rationale for the device stems from the time-critical nature of multiple rib fractures, as their presence is predictive of poor clinical outcomes, including respiratory failure and mortality, and is incorporated into US clinical guidelines for trauma patient management; flail chest, a subset condition, is potentially life-threatening. The underlying technology employs a deep learning algorithm trained on medical images. A retrospective, blinded, multicenter study on 200 CT chest cases (from GE and Siemens scanners, >1mm slice thickness) evaluated its performance, yielding a sensitivity of 92.7% and a specificity of 84.7% (AUC 0.939) for identifying multiple acute rib fractures. The study acknowledged that distinguishing between acute and certain chronic fractures (like pseudoarthrosis or malunion) can be challenging, potentially lowering specificity for purely acute fractures, but such ambiguous cases are still deemed clinically relevant for review to exclude acute injury. The average time-to-notification for 76 true positive studies was 69.56 seconds, which was noted as comparable to the 61.36 seconds reported for the HealthVCF software.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

uAI EasyTriage-RibCT chest imagesRib fracturesArtificial intelligenceTriage softwareWorkflow prioritizationRadiologyTrauma studiesNotification systemDeep learning

Device Metadata

Submission Number
K193271
Company
Shanghai United Imaging Intelligence Co., Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the uAI EasyTriage-Rib algorithm specifically differentiate between acute fractures, chronic fractures (e.g., pseudoarthrosis, malunion), and other bone abnormalities on CT chest images, and what is the false positive rate for each category?; What were the specific inclusion/exclusion criteria for the 200 cases in the performance study, particularly regarding patient demographics, trauma mechanisms, and types/severities of rib fractures?; How does the system's performance (sensitivity, specificity, time-to-notification) vary with different CT scanner manufacturers, models, and imaging protocols (e.g., slice thickness, contrast administration)?; What mechanisms are in place to monitor the real-world performance of the uAI EasyTriage-Rib post-deployment, and how are algorithm updates handled to maintain or improve accuracy over time?; Beyond flagging studies, does the uAI EasyTriage-Rib offer any features to quantify the extent of rib fractures (e.g., number of fractures, displacement, presence of flail chest segment) to further aid in prioritization or clinical assessment?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score30/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(deep learning, algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(server, network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(deployment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
uAI EasyTriage-Rib - Shanghai United Imaging Intelligence Co., Ltd. | ESL FDA AI Device Intelligence