Medscape Medical NewsAll articles

CorInsights MRI

ADM Diagnostics, Inc. • Radiology • 11/20/2020

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

CorInsights MRI is an automated software that quantifies brain structure volumes from T1-weighted MR images using an atlas-based segmentation methodology and comparison to an internal normative reference database. It aims to provide clinicians and researchers with objective, quantitative morphometric data to assist in evaluating structural brain changes in adults aged 45 to 95, with its efficacy supported by validation studies demonstrating high accuracy and reproducibility across diverse clinical cohorts and imaging parameters.

Summary

CorInsights MRI is a fully automated medical image processing software designed to perform automatic labeling, visualization, and volumetric quantification of identifiable brain structures using DICOM formatted T1-weighted magnetic resonance images. The software produces a PDF report containing morphometric measurements, which are compared to age and gender-matched reference percentile data, and an annotated DICOM image displaying anatomical structure boundaries with color overlays. Its internal architecture features a proprietary process involving artifact correction, atlas-based segmentation, volume calculation, and report generation, complemented by automated quality control measures such as image header checks and tissue contrast verification. CorInsights MRI is intended for adults aged 45 to 95 and serves as a support tool for medical professionals and clinical researchers in the assessment of structural MRIs. The device's performance was substantiated through comprehensive testing. Accuracy evaluations, using manually segmented ground truth data, demonstrated high performance for hippocampal volume (IntraClass Correlation coefficient [ICC] 0.95, DICE coefficient 83%), total gray matter volume (ICC 0.99, DICE 95%), intracranial volume (ICC 0.89, DICE 95%), and ventricular volumes (ICC 0.98, DICE ~87-88%). Reproducibility was also high, with an average test-retest ICC of 0.97. A normative reference database was established from 600 cognitively normal individuals (ages 42-95), carefully screened for amyloid pathology and other neurological confounders. Further validation involved over 1,400 scans from more than 1,100 individuals, encompassing a wide range of clinical diagnoses (cognitively normal, Mild Cognitive Impairment, Alzheimer's disease variants, non-Alzheimer's dementias) and various MRI scanner models (Siemens, GE, Philips) and field strengths (1.5T, 3T), confirming that the software's volumetric measurements align with established findings in peer-reviewed literature for these patient populations.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

MRIBrain VolumetryImage Processing SoftwareSegmentationDICOMNormative DataNeuroimagingMorphometryHippocampal VolumeCortical Segmentation

Device Metadata

Submission Number
K193287
Company
ADM Diagnostics, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
quantification/feature localization

Relevant Clinical Questions

  • Q1. How does the atlas-based segmentation algorithm adapt to significant anatomical variability observed in advanced stages of neurodegenerative diseases or across diverse populations not extensively represented in the normative database?; What are the specific artifact correction methods implemented in CorInsights MRI, and what is their quantified impact on segmentation accuracy and volumetric measurements under various common MR artifact conditions (e.g., motion, Gibbs ringing, intensity inhomogeneity)?; Considering the manual ground truth segmentations were generated by 'neuroanatomy experts,' what was the protocol for ensuring inter-expert consistency, and what were the measured inter-rater reliability scores for these ground truth datasets?; What is the longitudinal stability of CorInsights MRI's volumetric measurements, and how does it account for potential scanner upgrades or protocol changes when tracking individual patient changes over time?; How does CorInsights MRI's performance, particularly in measuring subtle volumetric changes in structures like the hippocampus, compare when using MR images acquired with accelerated sequences versus non-accelerated sequences, beyond general validation across both types?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score5/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm, dataset, ground truth, labeling)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
CorInsights MRI - ADM Diagnostics, Inc. | ESL FDA AI Device Intelligence