FastStroke, CT Perfusion 4D
GE Medical Systems SCS • Radiology • 11/12/2020
Device Purpose
The FastStroke and CT Perfusion 4D NeuroPackage is a software solution designed to enhance stroke diagnosis and assessment by providing advanced CT image analysis, including multiphase vascular visualization and quantitative perfusion mapping. It leverages deep learning for automated brain ventricle segmentation and offers a streamlined workflow with features like integrated applications and automated reporting to improve clinical efficiency.
Summary
NeuroPackage is a medical software solution combining FastStroke and CT Perfusion 4D applications to streamline CT stroke workflow. FastStroke is a CT image analysis tool designed to display head and neck vasculature from DICOM 3.0 CT scans at various enhancement time points, offering optimized, synchronized review formats and fusing multiphase vascular data into a single colorized view to aid in visualizing collateral vessels for stroke patient evaluation. CT Perfusion 4D analyzes dynamic CT perfusion images, post-contrast injection, to quantify parameters like regional blood flow, volume, mean transit time, and capillary permeability. These results, presented as parametric images, assist in assessing changes related to stroke or tumor angiogenesis and their treatment. The updated NeuroPackage integrates these two applications seamlessly within the FastStroke interface. Key technological advancements in the modified CT Perfusion 4D include the use of a deep learning convolutional neural network for automated brain ventricle segmentation, replacing a manual thresholding method. It also offers more flexibility in tissue classification by allowing users to select from multiple input parameters (Blood Volume, Blood Flow, TMax, MTT). Both FastStroke and CT Perfusion 4D now feature an automated email notification capability for distributing reports and results, aiming to improve workflow efficiency. Performance testing confirmed the deep learning algorithm's accuracy against expert annotations and overall software validation indicated no new safety or effectiveness concerns.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. What is the quantitative improvement in brain ventricle segmentation accuracy and processing time achieved by the deep learning algorithm compared to the predicate's HU thresholding method?; How does the expanded selection of input parameters (Blood Volume, Blood Flow, TMax, MTT) for tissue classification in CT Perfusion 4D impact diagnostic interpretation or treatment planning for stroke and tumor angiogenesis compared to the previous restricted options?; What specific clinical scenarios or patient populations benefit most from the fused multiphase vascular information and collateral vessel visualization provided by FastStroke?; Are there any limitations or contraindications for using the deep learning-based ventricle segmentation, particularly in cases with atypical brain anatomy or significant pathology?; How does the automated email notification feature integrate with existing hospital Picture Archiving and Communication Systems (PACS) and electronic health record (EHR) systems, and what data security measures are in place for transmitting patient information?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly