PROView
GE Medical Systems SCS • Radiology • 11/17/2020
Device Purpose
PROView is an MR image analysis software designed to assist clinicians by providing a guided workflow for reviewing multi-parametric prostate MR images, utilizing a deep learning algorithm for automatic prostate segmentation and PI-RADS v2.1 compliant lesion assessment. The system aims to enhance the analysis of prostate volume and lesions, generating standardized reports to support diagnostic and treatment planning processes for patients with suspected prostate conditions.
Summary
PROView is a medical diagnostic software intended to assist clinicians, radiologists, and physicians in the review and analysis of multi-parametric prostate magnetic resonance (MR) images. Its primary purpose is to support the assessment of prostate gland volume and the analysis of findings in patients with known or suspected prostate lesions, adhering to PI-RADS guidelines. The software facilitates the communication of clinically relevant information, including measurements and associated scoring, to referring physicians through a comprehensive report, thereby aiding in diagnosis and treatment planning. The PROView system offers a guided workflow for processing, analyzing, and reviewing 3D reconstructed images from MR scanning devices, focusing on multi-parametric prostate exams from a single date. Key features include automatic prostate volume calculation using a deep learning algorithm for organ segmentation, with an option for manual adjustment if the automatic segmentation is unsatisfactory. It also provides tools for PSA Density calculation, mapping and measurement of lesions, and scoring of T2-weighted, diffusion-weighted imaging (DWI), and dynamic contrast-enhanced (DCE) acquisitions. All analyses and measurements are compiled into an automatically generated report compliant with PI-RADS™ v2.1 guidelines.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the performance of PROView's deep learning algorithm for automatic prostate segmentation compare to manual segmentation by experienced radiologists in terms of accuracy, inter-observer variability, and time efficiency across diverse patient cohorts?; What is the range of accuracy for the automatic prostate volume calculation, and how does this variability impact the calculated PSA Density and subsequent clinical interpretations based on PI-RADS v2.1?; Are there specific MR image characteristics (e.g., field strength, sequence parameters, presence of artifacts) that significantly affect the reliability of the automatic segmentation and lesion scoring features of PROView?; How does PROView address challenging cases, such as post-treatment changes, large or irregularly shaped glands, or equivocal lesions, within its PI-RADS v2.1 framework?; What validation studies have been conducted to demonstrate the clinical utility of PROView in improving diagnostic accuracy or inter-reader agreement for prostate lesion assessment compared to conventional reading without the software?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class C (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly