NinesAI

Nines, Inc. • Radiology • 04/21/2020

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

NinesAI is an artificial intelligence-driven software that analyzes non-contrast head CT images to detect suspected intracranial hemorrhage and mass effect, functioning as a triage tool to help radiologists prioritize their review workflow. It utilizes machine learning algorithms to automatically identify critical findings from DICOM images within a PACS environment, providing rapid notifications to clinicians.

Summary

NinesAI is a radiological computer-aided triage and notification software designed for hospital networks and trained clinicians. It functions as a parallel workflow tool, employing artificial intelligence algorithms to analyze non-contrast head CT images for findings suggestive of emergent clinical conditions, specifically intracranial hemorrhage and mass effect. The system automatically processes Digital Imaging and Communications in Medicine (DICOM) images as they arrive in the Picture Archive and Communication System (PACS) using two distinct machine learning algorithms for each respective finding. Its purpose is to aid in prioritizing radiological review by identifying and alerting radiologists to images with potential emergent findings on their worklist, and it is not intended for diagnostic use beyond notification or to replace full patient evaluation. Preview images displayed are non-diagnostic. Performance testing evaluated the efficacy and safety of NinesAI's machine learning algorithms. For intracranial hemorrhage detection, the algorithm demonstrated a sensitivity of 0.899 and a specificity of 0.974. For mass effect detection, the sensitivity was 0.964 and specificity was 0.911. Both algorithms achieved primary endpoint goals of over 0.80 for sensitivity and specificity, using test datasets from over 20 clinical sites and multiple scanner manufacturers. A time-benefit analysis showed NinesAI provided significantly faster notification (mean 0.23 minutes) compared to standard of care time-to-open-dictation (e.g., 159.4 minutes for intracranial hemorrhage and 28.5 minutes for mass effect), thereby facilitating quicker case prioritization.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

NinesAIArtificial IntelligenceMachine LearningHead CTIntracranial HemorrhageMass EffectTriageNotification SoftwareDICOMPACS

Device Metadata

Submission Number
K193351
Company
Nines, Inc.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the NinesAI algorithm differentiate between various subtypes of intracranial hemorrhage (e.g., epidural, subdural, subarachnoid, intraparenchymal) and does its sensitivity vary among them?; What is the performance of NinesAI in populations with subtle or atypical presentations of intracranial hemorrhage or mass effect?; How robust is the NinesAI system to variations in CT image quality, acquisition parameters, or artifacts across different institutions and scanner types beyond those tested?; What is the learning curve and training requirement for radiologists to effectively integrate NinesAI notifications into their existing workflow without over-reliance or excessive dismissal of alerts?; Beyond time-to-notification, has any data been collected on the impact of NinesAI on patient outcomes or overall radiologist reading efficiency and diagnostic accuracy for cases not flagged by the AI?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score15/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment⚠ Not mentioned in summary
Postmarket Plan⚠ Not mentioned in summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(machine learning, algorithm, dataset)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials(network)
✓ Detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials(environment)
✓ Detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM, SaaSBOM, OBOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.

• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.

Preparing a similar submission?

ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.

Assess Your Readiness →Or contact ESL directly
NinesAI - Nines, Inc. | ESL FDA AI Device Intelligence