Viz ICH
Viz.ai, Inc. • Radiology • 03/18/2020
Device Purpose
Viz ICH is a software tool that employs an artificial intelligence algorithm to analyze non-contrast CT (NCCT) images of the brain for suspected intracranial hemorrhage (ICH). Its purpose is to provide rapid notification to specialists, operating as a parallel workflow tool to expedite triage and review of critical cases in acute settings.
Summary
Viz ICH is a notification-only, parallel workflow software tool designed for hospital networks and trained clinicians. It utilizes an artificial intelligence algorithm to analyze non-contrast CT (NCCT) images of the brain, specifically in acute settings, to identify findings suggestive of intracranial hemorrhage (ICH). Upon detecting a suspected ICH, the system sends a notification to a pre-determined neurovascular or neurosurgical specialist, recommending review of the images. While images can be previewed through a mobile application, these are compressed and intended for informational purposes only, not for diagnostic use beyond notification; clinicians must view non-compressed images on a diagnostic viewer for care-related decisions. The performance of Viz ICH was evaluated in a retrospective study involving 261 NCCT scans. The image analysis algorithm demonstrated a sensitivity of 93% and a specificity of 90% in detecting ICH compared to ground truth established by neuro-radiologists, with an AUC of 0.96. A key finding was the significantly reduced time to specialist notification, averaging 0.49 minutes with Viz ICH compared to 38.2 minutes for standard care. Performance was also stratified by variables including clinical site, patient age, gender, ICH subtype (with SAH showing lower sensitivity), slice thickness, and ICH volume. The device is contraindicated for use with NCCT scans from manufacturers other than General Electric (GE) or its subsidiaries.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the AI algorithm's performance vary with subtle or atypical presentations of intracranial hemorrhage, and what is its false negative rate for ICH subtypes like Subarachnoid Hemorrhage where sensitivity was lower (60%)?; What are the specific technical reasons for the contraindication against non-GE scanners, and are there plans to validate the algorithm on images from other major CT manufacturers?; How does the Viz ICH system integrate with existing hospital Picture Archiving and Communication Systems (PACS) and Electronic Health Records (EHR) beyond DICOM image transfer?; What is the impact of image compression on the mobile application's preview, and what measures are in place to mitigate potential misinterpretation if clinicians inadvertently use it beyond initial notification awareness?; Beyond time-to-notification, what evidence exists or is being collected regarding the impact of Viz ICH on patient outcomes, such as reduced time to intervention or improved neurological recovery?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.