Neuro.Al Algorithm
TeraRecon, Inc. • Radiology • 11/06/2020
Device Purpose
The Neuro.AI Algorithm is an advanced image processing software designed to assist clinicians by analyzing CT and MRI brain scans for detailed perfusion characteristics, including motion correction and calculation of multiple hemodynamic parameters. Utilizing methodologies such as parametric mapping and rotational MIP displays, it provides quantitative and visual data, validated through performance testing, to support diagnostic decision-making in neurological assessments, delivering results in DICOM format for broad compatibility.
Summary
The Neuro.AI Algorithm is a standalone image processing software designed for trained medical professionals to aid in the diagnosis of brain conditions. It processes static, functional, dynamic, and derived imaging datasets acquired from CT or MRI scans to analyze brain perfusion, incorporating motion correction and calculating key hemodynamic parameters such as time to peak (TTP), mean transit time (MTT), blood volume (BV/CBV), and blood flow (BF/CBF). The software generates outputs including parametric maps, classification maps, and reformatted images, with options to include or exclude brain ventricles in calculations, alongside vascular assessment through rotational Maximum Intensity Projections (MIP), known as the "tumble view," providing a comprehensive analytical view of brain tissue perfusion and vascular structures. The Neuro.AI Algorithm delivers its analytical outputs, validated through performance testing to meet its specified requirements, in DICOM format. These results, encompassing text and parametric map displays, can be viewed on various systems like TeraRecon's iNtuition or Northstar AI Results Explorer, as well as third-party PACS, facilitating 2D and 3D visualization. Deployable as a Microsoft Windows executable or a containerized application on standard hardware or cloud platforms, it utilizes methods like Singular Value Decomposition (SVD) for mathematical modeling. The algorithm is intended as a supporting tool to enhance diagnostic workflows and communication for physicians, who retain ultimate responsibility for clinical decisions.
AI Regulatory Concerns
Powered by
Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.
Keywords
Device Metadata
Relevant Clinical Questions
- Q1. How does the algorithm's performance in motion correction compare across different levels of patient movement during CT/MRI acquisition?; What is the quantitative impact of including versus excluding brain ventricles in perfusion calculations on diagnostic accuracy for specific neurological conditions?; Can the "tumble view" (rotational MIP) feature be customized for different vascular territories or specific clinical queries, and what is its added diagnostic value over standard MIP?; How does the Neuro.AI Algorithm's performance (e.g., accuracy of TTP, MTT, CBF, CBV) compare when processing data from different CT/MRI scanner vendors and models?; What are the specific image quality prerequisites (e.g., slice thickness, contrast injection protocol) for optimal performance of the Neuro.AI algorithm in generating reliable perfusion maps?
Risk Classification
ESL AnalysisFDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement
Learn how Parasoft automates IEC 62304 compliance testing →Cybersecurity Evidence
Powered by SBOMator™Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.
Supply Chain BOM Evidence
Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.
Analysis:
• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.
• Evidence of ML-BOM, SaaSBOM, HBOM, OBOM detected in AI-generated device summary.
• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.
• Postmarket cybersecurity monitoring plan not clearly documented in AI-generated device summary.
• Not detected in AI-generated device summary: SBOM, CBOM, VDR/VEX. These may be present in the full FDA submission.
Preparing a similar submission?
ESL takes complete ownership of your software evidence work - SBOM & CVE remediation with SBOMator™, static analysis & unit testing with Parasoft, traceability, and full IEC 62304 lifecycle support.
Assess Your Readiness →Or contact ESL directly