Zebra Medical Vision Ltd. • Radiology • 07/16/2020

510(k)IEC 62304 Class B
FDA Summary PDF

Device Purpose

HealthMammo is an artificial intelligence-powered software designed to analyze 2D FFDM screening mammograms from validated systems, identify suspicious findings, and notify clinicians to enable worklist prioritization. Its methodology involves parallel processing of mammography studies using an AI algorithm, and its clinical utility is supported by performance data demonstrating high sensitivity, specificity, and an AUC of 0.9661 in a retrospective study.

Summary

HealthMammo by Zebra Medical Vision is a software solution employing an artificial intelligence algorithm to analyze 2D Full Field Digital Mammography (FFDM) screening exams from validated FFDM systems. Its purpose is to assist MQSA-qualified interpreting physicians by identifying mammograms with suspicious findings at the exam level and flagging them within the Picture Archiving and Communication System (PACS) or a dedicated Zebra Worklist. This notification facilitates prioritization of cases potentially requiring urgent review, operating in parallel with the standard care workflow without altering images or removing cases from the radiologist's worklist. The system includes modules for data input/validation, the core AI algorithm for analysis, PACS/workstation integration, and error reporting, aiming to reduce the time to alert physicians about potentially critical findings, though it does not provide a diagnosis or treatment recommendations. The device's performance was evaluated using a retrospective cohort of 835 anonymized 2D FFDM screening mammograms, encompassing 435 biopsy-confirmed cancer cases and 400 normal cases with two-year negative follow-up, considering confounding factors like lesion type, breast density, age, and histology. HealthMammo demonstrated an overall Area Under the ROC Curve (AUC) of 0.9661. Performance was validated at three operating points: 'standard mode' (sensitivity 89.89%, specificity 90.75%), 'high sensitivity' mode (sensitivity 94.02%, specificity 83.50%), and 'high specificity' mode (sensitivity 84.14%, specificity 94.00%). The average processing time for analysis and notification was reported as 2.9 minutes per study.

AI Regulatory Concerns

Powered byJev by TypeSafe AI

Jev reads the full FDA letter and returns calibrated concern probabilities per regulatory category. These are AI estimates, not regulatory advice.

Keywords

HealthMammoMammographyArtificial IntelligenceWorklist Prioritization2D FFDMSuspicious FindingsTriagePACSSensitivitySpecificity

Device Metadata

Submission Number
K200905
Company
Zebra Medical Vision Ltd.
Panel
Radiology
Product Code
N/A
Data Type
Images
Clinical Function
Assessment
AI Function
Analysis
AI Subclass
triage

Relevant Clinical Questions

  • Q1. How does the performance of HealthMammo vary across different breast densities, particularly in dense breasts where lesion detection is more challenging?; What is the real-world impact on radiologist workflow efficiency and reading times when HealthMammo is integrated, beyond simple case prioritization?; Are there specific types of suspicious findings (e.g., architectural distortions vs. masses vs. microcalcifications) for which the HealthMammo algorithm demonstrates higher or lower sensitivity and specificity?; How does HealthMammo's performance, potentially validated primarily on Hologic systems as suggested in the technical comparison, generalize to 2D FFDM images from a broader range of FFDM system manufacturers, especially compared to its vendor-agnostic predicate?; What are the computational resource requirements for implementing and scaling HealthMammo in diverse clinical settings, from small clinics to high-volume screening centers?

Risk Classification

ESL Analysis
FDA Device ClassII

FDA Class II via 510(k) pathway; IEC 62304 Class B (software safety classification); Authorized before §524B enforcement

Learn how Parasoft automates IEC 62304 compliance testing →

Cybersecurity Evidence

Powered by SBOMator™

Based on AI-generated device summaries, not the full FDA submission. Items not detected here may still be present in the complete submission package.

Cyber Score40/100
SBOM Evidence⚠ Not mentioned in summary
Cyber Risk Assessment✓ Detected in Summary
Postmarket Plan✓ Detected in Summary
§524B ApplicableNo

Supply Chain BOM Evidence

Based on the CycloneDX / OWASP ECMA-424 xBOM ecosystem. Detection is from the AI-generated summary.

SBOMSoftware Bill of Materials
- Not detected
ML-BOMMachine Learning Bill of Materials(algorithm)
✓ Detected
SaaSBOMSoftware-as-a-Service Bill of Materials
- Not detected
HBOMHardware Bill of Materials
- Not detected
CBOMCryptography Bill of Materials
- Not detected
VDR/VEXVulnerability Disclosure Report / Vulnerability Exploitability eXchange
- Not detected
OBOMOperations Bill of Materials
- Not detected

Analysis:

• Analysis is based on the AI-generated device summary, not the full FDA submission package. Click "Analyze Full FDA PDF" below to scan the actual submission document.

• Evidence of ML-BOM detected in AI-generated device summary.

• This device was authorized before §524B took effect. Cybersecurity evidence requirements were less prescriptive at the time.

• Not detected in AI-generated device summary: SBOM, SaaSBOM, HBOM, CBOM, VDR/VEX, OBOM. These may be present in the full FDA submission.